Model: HNAG920
Sampling Method: Pumping Suction and Diffusion
Detection Principle: PID
Gas: Methyl Bromide (CH3Br).
Range: 0 to 50/100/200/500/1000/2000/3000ppm
Resolution: 0.01ppm;0.1ppm;1ppm.
Accuracy: ≤±2% F.S.
Model: HNAG920
Sampling Method: Pumping Suction and Diffusion
Detection Principle: PID
Gas: Methyl Bromide (CH3Br).
Range: 0 to 50/100/200/500/1000/2000/3000ppm
Resolution: 0.01ppm;0.1ppm;1ppm.
Accuracy: ≤±2% F.S.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Handheld Single Gas Detector
✔️ Built-in internal sampling pump and diffusion sampling
✔️ Fall alarm / one-touch emergency alarm function.
✔️180° auto-rotating screen.
✔️Temperature & humidity compensation.
✔️Built-in buttons for easy parameter viewing and configuration.
✔️Features an external USB port for data export and deletion via USB cable connection to a computer.
✔️ Equipped with a 32-bit microprocessor and high-speed, high-precision processing circuitry for fast and accurate measurements.
✔️PC+TPU (rubber overmolding process) for impact resistance.
✔️Handheld and small design, easy to carry, can be put in a pocket.
✔️High-intensity ABS engineering plastics housing, suitable for different kinds of situations.
Gas Detection Q&A - For Your Safety Environments
Q1. What is methyl bromide?
A1:Methyl bromide, chemical formula CH₃Br, is a colorless, odorless, high-density gas that is liquid under standard temperature and pressure. It was widely used as a fumigant (for killing insects, fungi, and rodents) and as a chemical raw material. However, due to its ozone-depleting properties, its use as a fumigant has been phased out globally under the Montreal Protocol. Currently, only limited critical use exemptions (CUEs) and quarantine and pre-shipment (QPS) applications are permitted.
Q2. Where is methyl bromide typically found in the environment?
A2:The production of methyl bromide is primarily divided into anthropogenic use and natural generation:
Anthropogenic Use (Major Source):
• Agricultural and Storage Fumigation: Used for soil sterilization (to eradicate nematodes, fungi, weed seeds) and for fumigating warehouses, ship holds, and containers to control pests and pathogens. This was historically the primary use of methyl bromide.
• Chemical Manufacturing: Used as a methylating agent in the synthesis of pesticides, pharmaceuticals, dyes, and other chemical products.
• Fire Suppression: Was used as a substitute for Halon in fire extinguishing systems, but its use has largely been discontinued due to environmental concerns.
Natural Generation:
• Marine organisms (such as algae, phytoplankton) and certain fungi produce trace amounts of methyl bromide during metabolic processes, but the quantity is far less than anthropogenic emissions.
Q3. Why are reliable gas detectors and monitoring devices necessary?
A3:Due to its high toxicity, lack of color and odor (making it difficult to detect by human senses), and environmental hazards, reliable detection equipment is essential:
Life Safety (Acute Toxicity):
• Methyl bromide is a highly toxic substance that primarily damages the central nervous and respiratory systems. It lacks a distinctive warning odor (unlike chlorine or ammonia), and initial poisoning often has no obvious symptoms (latent phase). Once symptoms appear (such as headache, nausea, convulsions, pulmonary edema), the condition is often severe and can be fatal.
• Reliable detectors (such as Photoionization Detectors (PID) or electrochemical sensors) can monitor the concentration of methyl bromide in the air in real-time, ensuring that levels remain within safe limits for workers and preventing acute poisoning.
Occupational Health (Chronic Exposure):
• Long-term, low-level exposure to methyl bromide can lead to chronic health issues like neurological damage and liver/kidney impairment. Monitoring devices help assess long-term exposure levels in the workplace to ensure compliance with occupational health standards.
Environmental Compliance and Leak Control:
• Methyl bromide is an ozone-depleting substance (ODS), and its emissions are strictly regulated. During fumigation operations or chemical production, high-precision monitoring equipment like the Skyeaglee Methyl bromide gas detector is needed to detect any leaks, confirming that exhaust gases are effectively captured and treated to prevent illegal emissions.
Operational Safety and Efficiency:
• After fumigation, detectors are necessary to confirm that residual gas concentrations in the treated space have dropped to safe levels (e.g., below 5 ppm) before allowing re-entry or lifting isolation, ensuring the safety of subsequent operations.
Handheld Single Gas Detector
✔️ Built-in internal sampling pump and diffusion sampling
✔️ Fall alarm / one-touch emergency alarm function.
✔️180° auto-rotating screen.
✔️Temperature & humidity compensation.
✔️Built-in buttons for easy parameter viewing and configuration.
✔️Features an external USB port for data export and deletion via USB cable connection to a computer.
✔️ Equipped with a 32-bit microprocessor and high-speed, high-precision processing circuitry for fast and accurate measurements.
✔️PC+TPU (rubber overmolding process) for impact resistance.
✔️Handheld and small design, easy to carry, can be put in a pocket.
✔️High-intensity ABS engineering plastics housing, suitable for different kinds of situations.






Gas Detection Q&A - For Your Safety Environments
Q1. What is methyl bromide?
A1:Methyl bromide, chemical formula CH₃Br, is a colorless, odorless, high-density gas that is liquid under standard temperature and pressure. It was widely used as a fumigant (for killing insects, fungi, and rodents) and as a chemical raw material. However, due to its ozone-depleting properties, its use as a fumigant has been phased out globally under the Montreal Protocol. Currently, only limited critical use exemptions (CUEs) and quarantine and pre-shipment (QPS) applications are permitted.
Q2. Where is methyl bromide typically found in the environment?
A2:The production of methyl bromide is primarily divided into anthropogenic use and natural generation:
Anthropogenic Use (Major Source):
• Agricultural and Storage Fumigation: Used for soil sterilization (to eradicate nematodes, fungi, weed seeds) and for fumigating warehouses, ship holds, and containers to control pests and pathogens. This was historically the primary use of methyl bromide.
• Chemical Manufacturing: Used as a methylating agent in the synthesis of pesticides, pharmaceuticals, dyes, and other chemical products.
• Fire Suppression: Was used as a substitute for Halon in fire extinguishing systems, but its use has largely been discontinued due to environmental concerns.
Natural Generation:
• Marine organisms (such as algae, phytoplankton) and certain fungi produce trace amounts of methyl bromide during metabolic processes, but the quantity is far less than anthropogenic emissions.
Q3. Why are reliable gas detectors and monitoring devices necessary?
A3:Due to its high toxicity, lack of color and odor (making it difficult to detect by human senses), and environmental hazards, reliable detection equipment is essential:
Life Safety (Acute Toxicity):
• Methyl bromide is a highly toxic substance that primarily damages the central nervous and respiratory systems. It lacks a distinctive warning odor (unlike chlorine or ammonia), and initial poisoning often has no obvious symptoms (latent phase). Once symptoms appear (such as headache, nausea, convulsions, pulmonary edema), the condition is often severe and can be fatal.
• Reliable detectors (such as Photoionization Detectors (PID) or electrochemical sensors) can monitor the concentration of methyl bromide in the air in real-time, ensuring that levels remain within safe limits for workers and preventing acute poisoning.
Occupational Health (Chronic Exposure):
• Long-term, low-level exposure to methyl bromide can lead to chronic health issues like neurological damage and liver/kidney impairment. Monitoring devices help assess long-term exposure levels in the workplace to ensure compliance with occupational health standards.
Environmental Compliance and Leak Control:
• Methyl bromide is an ozone-depleting substance (ODS), and its emissions are strictly regulated. During fumigation operations or chemical production, high-precision monitoring equipment like the Skyeaglee Methyl bromide gas detector is needed to detect any leaks, confirming that exhaust gases are effectively captured and treated to prevent illegal emissions.
Operational Safety and Efficiency:
• After fumigation, detectors are necessary to confirm that residual gas concentrations in the treated space have dropped to safe levels (e.g., below 5 ppm) before allowing re-entry or lifting isolation, ensuring the safety of subsequent operations.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920