Model: HNAG1000-NH3
Detection: NH3
Detection Principle: Electrochemistry
Detection range: 0-100PPM
The HNAG1000-NH3 online ammonia gas concentration detector is engineered for real-time and precise monitoring of NH3 gas concentrations and hazardous leaks in demanding industrial environments. Utilizing advanced electrochemical testing principles and microcontroller technology, it delivers rapid response times (T90<10S), high measurement accuracy (±2%F.S), and exceptional stability.

Safety is paramount in chemical plants, cold storage facilities, and fertilizer manufacturing workshops. This NH3 gas detector features an explosion-proof wiring method with an Ex d IIC T6 rating, making it fully certified for hazardous industrial locations. Protected by a heavy-duty aluminum alloy housing with an IP66 protection grade, it effectively resists splashing water and short periods of rain.

This industrial gas alarm is compatible with various control alarms, PLCs, DCS, and DDC receiving equipment. It simultaneously delivers on-site warnings and remote signals through multiple channels:
Wired Outputs: Standard 12-bit precision 4-20mA current output and RS485 digital output (MODBUS RTU protocol, up to 1Km transmission).
Relay & Wireless Options: Passive contact relay switching output, alongside optional built-in LORA/ZigBee or external GPRS/4G modules for cloud platform monitoring.

Equipped with a 2.5-inch high-definition color screen, the unit clearly displays real-time concentration, temperature, and humidity. Thanks to the standard infrared remote control, operators can perform zero adjustments and calibration safely without opening the housing cover in hazardous zones.


Since ammonia is lighter than air, the detector should typically be mounted above potential leak sources, within 1 meter of the leakage point, and higher than 30 cm from the ground. Each unit comes standard with a detector, manual, remote control, and qualification certificate, with optional flow cells and 24V adapters available.


Q1: Where should the NH3 detector be installed relative to the leak source?
A1: Because ammonia gas is lighter than air, the detector should be installed above the potential leak source or equipment, within 1 meter of the leakage point, and at least 30 cm above the ground.
Q2: What is the maximum transmission distance for the 4-20mA and RS485 signals?
A2: Both the standard 4-20mA current output and the RS485 digital signal (MODBUS RTU protocol) support a stable transmission distance of up to 1 kilometer.
Q3: Can the detector be operated without opening its cover during maintenance?
A3: Yes. The included infrared remote control allows engineers to perform settings, zero-point calibration, and alarm checks safely without opening the flameproof housing in hazardous environments.
Q4: What are the IP and explosion-proof ratings of this NH3 detector?
A4: The device features an IP66 rating for superior waterproof and dustproof protection, alongside an Ex d IIC T6 explosion-proof certification for high-risk industrial safety applications.
Q5: How does the zero-point automatic tracking function work?
A5: The system automatically tracks the zero point to prevent signal drift over time and includes built-in temperature compensation to ensure long-term monitoring accuracy in fluctuating industrial environments.
Q6: Can this detector be linked directly to ventilation fans or solenoid valves?
A6: Yes. In addition to standard analog and digital outputs, the unit features a passive contact relay switching output (rated 220VAC/3A or 24VDC/3A) that can directly drive external equipment such as solenoid valves, exhaust fans, and alarms.
Q7: What optional accessories are available for extreme working conditions?
A7: We offer a variety of optional accessories including normal/high-temperature and high-humidity pretreatment systems, high-temperature and high-dust pretreatment systems, pressure-reducing valves, flow meters, external sampling pumps, and power adapters.
Q8: How does the device handle lightning or static electricity interference outdoors?
A8: The detector features an intrinsically safe circuit design with secondary lightning protection and anti-static capabilities that exceed national standards, allowing it to withstand high-intensity pulse surge current impacts safely.

The HNAG800-CLO2 Preprocessing Online Monitoring System delivers real-time Chlorine Dioxide detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response and high accuracy within a rugged stainless steel enclosure for strict industrial safety.

The HNAG800-CL2 Preprocessing Online Monitoring System delivers real-time Chlorine gas detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response and high accuracy within a rugged stainless steel enclosure for strict industrial safety.

The HNAG800-HF Preprocessing Online Monitoring System delivers real-time Hydrogen Fluoride detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response and high accuracy within a rugged stainless steel enclosure for robust industrial safety.

The HNAG800-F2 Preprocessing Online Monitoring System provides real-time Fluorine detection. Featuring a precise electrochemical sensor within a robust stainless steel enclosure, it ensures rapid response and high safety in harsh environments.

The HNAG800-HBR/HCL Preprocessing Online Monitoring System provides real-time Hydrogen Bromide and Hydrogen Chloride detection. Featuring a precise electrochemical sensor in a stainless steel enclosure, it ensures rapid response and industrial safety.

The HNAG800-HCN Preprocessing Online Monitoring System delivers real-time Hydrogen Cyanide detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response, high accuracy, and explosion-proof safety within a rugged stainless steel enclosure.

The HNAG800-NO Preprocessing Online Monitoring System delivers real-time Nitric Oxide detection. Featuring an advanced electrochemical sensor for atmospheric monitoring, it ensures rapid response and high precision in a rugged stainless steel enclosure.

The HNAG1000-EX split-type fixed combustible gas detector monitors EX gases (0-100%LEL) in hazardous zones. Featuring a catalytic combustion sensor, remote probe, aluminum alloy housing, and 4-20mA/RS485 outputs, it ensures industrial safety.

The HNAG1000-O2 fixed pump-suction O2 gas detector monitors trace oxygen (0-1000ppm). Built with an aluminum alloy housing, electrochemical sensor, IP66/Ex d IIC T6 ratings, and 4-20mA/RS485 outputs, it ensures continuous industrial safety.

The HNAG1000-NH3 fixed NH3 gas detector offers real-time ammonia monitoring (0-100PPM). Featuring electrochemical sensor, explosion-proof aluminum housing, and 4-20mA/RS485 outputs.

The HNAG1000-CO fixed CO gas detector ensures real-time carbon monoxide monitoring. Featuring an electrochemical sensor, explosion-proof design, and 4-20mA/RS485 outputs, it guarantees safety in industrial plants.

The HNAG900 VOC gas detector offers precise real-time monitoring of volatile organic compounds. Powered by electrochemical/PID sensors and adjustable pump suction, it features a 3.5-inch TFT screen, USB export, and Ex ib II CT4 Gb rating.

The fixed C2H4O gas detector (HNAG1000) provides real-time, accurate ethylene oxide monitoring (0-100 ppm). Featuring a precise electrochemical sensor, robust aluminum alloy housing, and IP66 protection, it ensures ultimate industrial safety.

Portable HNAG920 H2SO4 Gas Detector offers dual pump-suction and diffusion sampling. With a precision electrochemical sensor, 2.0-inch LCD, and durable PC+TPU housing, it ensures rapid, accurate sulfuric acid monitoring for safety.

The HNAG920-3H portable 3-in-1 gas detector monitors CH4, C3H8, and H2. Featuring integrated pump-suction and diffusion modes, a 180° auto-rotating screen, and wireless transmission, it provides superior safety in complex environments.

The HNAG1000-O3 fixed gas detector provides real-time, highly accurate ozone (O3) monitoring. Featuring an advanced electrochemical sensor, Ex d IIC T6 rating, and 4-20mA/RS485 outputs, it ensures maximum safety in demanding industrial environments.

The HNAG920-PH3 portable gas detector offers precise real-time phosphine monitoring. Featuring a dual pump-suction and diffusion design, 2.0-inch auto-rotating screen, and wireless data export, it ensures maximum safety in hazardous environments.

The HNAG1000-H2S is an industrial fixed hydrogen sulfide (H2S) gas detector featuring a rugged stainless steel enclosure. Equipped with a precise electrochemical sensor, it delivers real-time monitoring, multi-signal output, and IP66 protection.

The HNAG920-5H portable 5-in-1 gas detector supports both pump suction and diffusion modes. It monitors O2, H2S, CO2, CO, and N2 simultaneously with high accuracy, featuring wireless transmission, a 180° auto-rotating screen, and a durable PC+TPU housing.

The HNAG800-O3 Preprocessing Online Monitoring System provides real-time Ozone detection. Featuring an advanced electrochemical sensor in a stainless steel enclosure, it ensures rapid response and high precision for strict industrial safety.

The HNAG800-CLO2 Preprocessing Online Monitoring System delivers real-time Chlorine Dioxide detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response and high accuracy within a rugged stainless steel enclosure for strict industrial safety.

The HNAG800-CL2 Preprocessing Online Monitoring System delivers real-time Chlorine gas detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response and high accuracy within a rugged stainless steel enclosure for strict industrial safety.

The HNAG800-HF Preprocessing Online Monitoring System delivers real-time Hydrogen Fluoride detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response and high accuracy within a rugged stainless steel enclosure for robust industrial safety.

The HNAG800-F2 Preprocessing Online Monitoring System provides real-time Fluorine detection. Featuring a precise electrochemical sensor within a robust stainless steel enclosure, it ensures rapid response and high safety in harsh environments.

The HNAG800-HBR/HCL Preprocessing Online Monitoring System provides real-time Hydrogen Bromide and Hydrogen Chloride detection. Featuring a precise electrochemical sensor in a stainless steel enclosure, it ensures rapid response and industrial safety.

The HNAG800-HCN Preprocessing Online Monitoring System delivers real-time Hydrogen Cyanide detection. Featuring a highly sensitive electrochemical sensor, it ensures rapid response, high accuracy, and explosion-proof safety within a rugged stainless steel enclosure.

The HNAG800-NO Preprocessing Online Monitoring System delivers real-time Nitric Oxide detection. Featuring an advanced electrochemical sensor for atmospheric monitoring, it ensures rapid response and high precision in a rugged stainless steel enclosure.

The HNAG1000-EX split-type fixed combustible gas detector monitors EX gases (0-100%LEL) in hazardous zones. Featuring a catalytic combustion sensor, remote probe, aluminum alloy housing, and 4-20mA/RS485 outputs, it ensures industrial safety.

The HNAG1000-O2 fixed pump-suction O2 gas detector monitors trace oxygen (0-1000ppm). Built with an aluminum alloy housing, electrochemical sensor, IP66/Ex d IIC T6 ratings, and 4-20mA/RS485 outputs, it ensures continuous industrial safety.

The HNAG1000-NH3 fixed NH3 gas detector offers real-time ammonia monitoring (0-100PPM). Featuring electrochemical sensor, explosion-proof aluminum housing, and 4-20mA/RS485 outputs.

The HNAG1000-CO fixed CO gas detector ensures real-time carbon monoxide monitoring. Featuring an electrochemical sensor, explosion-proof design, and 4-20mA/RS485 outputs, it guarantees safety in industrial plants.

The HNAG900 VOC gas detector offers precise real-time monitoring of volatile organic compounds. Powered by electrochemical/PID sensors and adjustable pump suction, it features a 3.5-inch TFT screen, USB export, and Ex ib II CT4 Gb rating.

The fixed C2H4O gas detector (HNAG1000) provides real-time, accurate ethylene oxide monitoring (0-100 ppm). Featuring a precise electrochemical sensor, robust aluminum alloy housing, and IP66 protection, it ensures ultimate industrial safety.

Portable HNAG920 H2SO4 Gas Detector offers dual pump-suction and diffusion sampling. With a precision electrochemical sensor, 2.0-inch LCD, and durable PC+TPU housing, it ensures rapid, accurate sulfuric acid monitoring for safety.