multi gas detector 4 gas H2S CH4 CO O2 analyzer


Detection gas:H2S CH4 CO O2

Range:H2S:0-100ppm/CH4:0-100%LEL/CO:0-1000ppm/O2;0-30%VOL/custom

Detection Principle:Catalytic combustion / Electrochemical / Infrared

Resolution:H2S:0.1ppm/CH4:0.1%LEL/CO:1ppm/O2;0.01%VOL/custom

Detection Accuracy:±2%F.S

Model:SK/MIC-800

Detection gas:H2S CH4 CO O2

Range:H2S:0-100ppm/CH4:0-100%LEL/CO:0-1000ppm/O2;0-30%VOL/custom

Detection Principle:Catalytic combustion / Electrochemical / Infrared

Resolution:H2S:0.1ppm/CH4:0.1%LEL/CO:1ppm/O2;0.01%VOL/custom

Detection Accuracy:±2%F.S

Model:SK/MIC-800



Product Description

Portable Gas Detector Parameter Table

Measure gas

H2S CH4 CO O2

Detection principle

IR / Catalytic Combustion/ Electrochemistry/PID/custom

range

H2S:0-100ppm

CH4:0-100%LEL

CO:0-1000ppm

O2;0-30%VOL/custom

Resolution

H2S:0.1ppm

CH4:0.1%LEL

CO:1ppm

O2:0.01%VOL

Sampling accuracy

±2%F.S

Response time

T90<10S

Working temperature

-20  50

Working humidity

0-95%RH

Screen size

3.5-inch LCD

Charging interface

5VDC

Battery capacity

5400mA

Working air pressure

86kpa-106kpa

Working voltage

DC5V±1%/DC24±1%

Output method

USB

Sampling method

Pump suction

Warranty period

1years

External dimensions

230×95×65mm

Sensor service life

1-3years

Protection grade

IP65

Explosion-proof grade

Ex ib ll CT4 Gb

Data storage

100,000 entries

Alarm record

1000 items

Alarm Settings

The standard configuration is two-level alarm, and the alarm mode can be set: high and low alarm

Calibration method

Primary calibration, secondary calibration, and tertiary calibration

Optional accessories

High-temperature sampling handle (Customized sampling handles of different temperatures according to the detection temperature)

Product features of Portable Multi Gas concentration detector

● Utilizes imported sensors and a 32-bit high-performance processor, coupled with high-speed, high-precision processing circuitry, to achieve rapid and accurate detection.
● Equipped with a USB interface, supporting easy data export and deletion via a computer connection.
● Capable of simultaneously detecting 1 to 6 types of gases.
● Multi-functional configuration options.
● Supports coefficient adjustment, enabling free switching between common units such as ppm and mg/m³.
Stores historical data and alarm records.

Product advantages

Precautions for Use

● When charging the detector, please do so in a safe place and use a 5V 2A or higher charger that complies with safety regulations

● When using the detector for the first time, please fully charge the battery before use

● This detector is of pump suction type. Please do not block the air inlet and outlet of the detector to avoid clogging of the internal air pump. If the air pump fails to start after a blockage occurs, it should be shut down quickly and then restarted.

● If you need to test for a long time, please fully charge the battery first. When the battery power drops to 0%, a countdown and automatic shutdown interface will appear. You can force it to turn on, and it will automatically shut down again after 5 minutes.

● When in daily use, do not impact the detector with gas exceeding the measurement range to avoid irreversible damage.

● Do not use in harsh environments such as high temperature, high pressure or high humidity. If the humidity of the usage environment is high, filter and dehumidify before conducting the test.

● The detector should be prevented from falling from a height or being subjected to violent vibration.

● If the sensor malfunctions, please contact the after-sales service of the manufacturer.

● Under normal use, the effective service life of the sensor of the detector is 24 to 36 months. During the valid service life, the sensor should be calibrated and inspected regularly every six months or once a year (depending on the working environment) to ensure the accuracy and effectiveness of gas monitoring. Sensors that have exceeded their valid service life or are faulty must be replaced.

Main application scenarios

Petroleum, Natural Gas, and Petrochemical Industry:
Scenarios: Drilling platforms, refineries, chemical plants, pump stations, internal maintenance of oil tanks/storage tanks, pipeline inspection and maintenance, underground operations at gas stations.
Corresponding Gases: H2S (associated gas from crude oil), CH4 (main component of natural gas, flammable), O2 (monitoring for oxygen deficiency in confined spaces).
 
Utilities and Municipal Operations:
Scenarios: Maintenance and cleaning of sewers, wastewater wells, septic tanks, biogas digesters; water treatment plants; gas pipeline maintenance.
Corresponding Gases: H2S (produced by sewage fermentation), CH4 (biogas), CO (incomplete combustion), O2 (prone to oxygen deficiency).
 
Firefighting and Emergency Rescue:
Scenarios: Entering fire scenes, underground space rescues, hazardous chemical leakage incidents.
Corresponding Gases: CO (main lethal gas after fires), O2 (assessing survivable environment), CH4 (assessing explosion risks from flammable gases), other volatile organic compounds (typically detected with flammable gas sensors as supplementary).
 
Confined Space Operations (involved in almost all industries):
Scenarios: Pre-entry detection and continuous monitoring during operations in ship cabins, underground tunnels, reaction vessels, storage silos, grain silos, fermentation tanks, basements, etc.
Corresponding Gases: O2 (primary detection to prevent asphyxiation), CO (may be produced by internal equipment), H2S (produced by decaying matter), CH4 (biogas or leaks).
 
Manufacturing and Heavy Industry:
Scenarios: Steel plants, foundries (prone to CO production), coal mining (CH4 gas, CO), food processing plants (insufficient O2 in cold storage, H2S from fermentation), semiconductor manufacturing.
Corresponding Gases: Selected based on risk points of different processes.
 
Public Facility Installation and Maintenance:
Scenarios: Boiler rooms, heating systems, ventilation monitoring in underground garages, exhaust monitoring in parking lots.

Corresponding Gases: CO (incomplete combustion of fuels), O2 (consumed by combustion), CH4 (gas leaks).

Main application scenarios
Petroleum, Natural Gas, and Petrochemical Industry:
Scenarios: Drilling platforms, refineries, chemical plants, pump stations, internal maintenance of oil tanks/storage tanks, pipeline inspection and maintenance, underground operations at gas stations.
Corresponding Gases: H2S (associated gas from crude oil), CH4 (main component of natural gas, flammable), O2 (monitoring for oxygen deficiency in confined spaces).
 
Utilities and Municipal Operations:
Scenarios: Maintenance and cleaning of sewers, wastewater wells, septic tanks, biogas digesters; water treatment plants; gas pipeline maintenance.
Corresponding Gases: H2S (produced by sewage fermentation), CH4 (biogas), CO (incomplete combustion), O2 (prone to oxygen deficiency).
 
Firefighting and Emergency Rescue:
Scenarios: Entering fire scenes, underground space rescues, hazardous chemical leakage incidents.
Corresponding Gases: CO (main lethal gas after fires), O2 (assessing survivable environment), CH4 (assessing explosion risks from flammable gases), other volatile organic compounds (typically detected with flammable gas sensors as supplementary).
 
Confined Space Operations (involved in almost all industries):
Scenarios: Pre-entry detection and continuous monitoring during operations in ship cabins, underground tunnels, reaction vessels, storage silos, grain silos, fermentation tanks, basements, etc.
Corresponding Gases: O2 (primary detection to prevent asphyxiation), CO (may be produced by internal equipment), H2S (produced by decaying matter), CH4 (biogas or leaks).
 
Manufacturing and Heavy Industry:
Scenarios: Steel plants, foundries (prone to CO production), coal mining (CH4 gas, CO), food processing plants (insufficient O2 in cold storage, H2S from fermentation), semiconductor manufacturing.
Corresponding Gases: Selected based on risk points of different processes.
 
Public Facility Installation and Maintenance:
Scenarios: Boiler rooms, heating systems, ventilation monitoring in underground garages, exhaust monitoring in parking lots.
Corresponding Gases: CO (incomplete combustion of fuels), O2 (consumed by combustion), CH4 (gas leaks).

 

Product Recommendation
1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

47629257-f1ea-4eec-bc53-de26a94fac2e.jpeg

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument-SK/MIC-7500

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

(1).jpg

handheld helium leak detector He analyzer-HNAG900

handheld helium leak detector He analyzer

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

(2).jpg

Handheld ozone detector O3 monitor-HNAG900

Handheld ozone detector O3 monitor

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

15.jpg

handheld Hydrogen Fluoride gas detector HF-HNAG920

handheld Hydrogen Fluoride gas detector HF

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

16.jpg

Portable Ethanol analyzer C2H6O ppm-HNAG920

Portable Ethanol analyzer C2H6O ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

12-12-新款主图.jpg

Pump suction portable Ethylene gas detector C2H4 0-100ppm-HNAG920

Pump suction portable Ethylene gas detector C2H4 0-100ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Give us a free quote
Submit this form and our sales representative will contact you soon.
* Name
* Email
Phone
  • Angola+244
  • Afghanistan+93
  • Albania+355
  • Algeria+213
  • Andorra+376
  • Anguilla+1264
  • Antigua and Barbuda+1268
  • Argentina+54
  • Armenia+374
  • Ascension+247
  • Australia+61
  • Austria+43
  • Azerbaijan+994
  • Bahamas+1242
  • Bahrain+973
  • Bangladesh+880
  • Barbados+1246
  • Belarus+375
  • Belgium+32
  • Belize+501
  • Benin+229
  • Bermuda Is.+1441
  • Bolivia+591
  • Botswana+267
  • Brazil+55
  • Brunei+673
  • Bulgaria+359
  • Burkina+faso+226
  • Burma+95
  • Burundi+257
  • Cameroon+237
  • Canada+1
  • Cayman Is.+1345
  • Central African Republic+236
  • Chad+235
  • Chile+56
  • China+86
  • Colombia+57
  • Congo+242
  • Cook Is.+682
  • Costa Rica+506
  • Cuba+53
  • Cyprus+357
  • Czech Republic+420
  • Denmark+45
  • Djibouti+253
  • Dominica Rep.+1890
  • Ecuador+593
  • Egypt+20
  • EI Salvador+503
  • Estonia+372
  • Ethiopia+251
  • Fiji+679
  • Finland+358
  • France+33
  • French Guiana+594
  • Gabon+241
  • Gambia+220
  • Georgia+995
  • Germany+49
  • Ghana+233
  • Gibraltar+350
  • Greece+30
  • Grenada+1809
  • Guam+1671
  • Guatemala+502
  • Guinea+224
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hongkong+852
  • Hungary+36
  • Iceland+354
  • India+91
  • Indonesia+62
  • Iran+98
  • Iraq+964
  • Ireland+353
  • Israel+972
  • Italy+39
  • Ivory Coast+225
  • Jamaica+1876
  • Japan+81
  • Jordan+962
  • Kampuchea (Cambodia )+855
  • Kazakstan+327
  • Kenya+254
  • Korea+82
  • Kuwait+965
  • Kyrgyzstan+331
  • Laos+856
  • Latvia+371
  • Lebanon+961
  • Lesotho+266
  • Liberia+231
  • Libya+218
  • Liechtenstein+423
  • Lithuania+370
  • Luxembourg+352
  • Macao+853
  • Madagascar+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Mariana Is+1670
  • Martinique+596
  • Mauritius+230
  • Mexico+52
  • Moldova, Republic of+373
  • Monaco+377
  • Mongolia+976
  • Montserrat Is+1664
  • Morocco+212
  • Mozambique+258
  • Namibia+264
  • Nauru+674
  • Nepal+977
  • Netheriands Antilles+599
  • Netherlands+31
  • New Zealand+64
  • Nicaragua+505
  • Niger+227
  • Nigeria+234
  • North Korea+850
  • Norway+47
  • Oman+968
  • Pakistan+92
  • Panama+507
  • Papua New Cuinea+675
  • Paraguay+595
  • Peru+51
  • Philippines+63
  • Poland+48
  • French Polynesia+689
  • Portugal+351
  • Puerto Rico+1787
  • Qatar+974
  • Reunion+262
  • Romania+40
  • Russia+7
  • Saint Lueia+1758
  • Saint Vincent+1784
  • Samoa Eastern+684
  • Samoa Western+685
  • San Marino+378
  • Sao Tome and Principe+239
  • Saudi Arabia+966
  • Senegal+221
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Slovakia+421
  • Slovenia+386
  • Solomon Is+677
  • Somali+252
  • South Africa+27
  • Spain+34
  • Sri Lanka+94
  • St.Lucia+1758
  • St.Vincent+1784
  • Sudan+249
  • Suriname+597
  • Swaziland+268
  • Sweden+46
  • Switzerland+41
  • Syria+963
  • Taiwan+886
  • Tajikstan+992
  • Tanzania+255
  • Thailand+66
  • Togo+228
  • Tonga+676
  • Trinidad and Tobago+1809
  • Tunisia+216
  • Turkey+90
  • Turkmenistan+993
  • Uganda+256
  • Ukraine+380
  • United Arab Emirates+971
  • United Kiongdom+44
  • United States of America+1
  • Uruguay+598
  • Uzbekistan+233
  • Venezuela+58
  • Vietnam+84
  • Yemen+967
  • Yugoslavia+381
  • Zimbabwe+263
  • Zaire+243
  • Zambia+260
* Message