Handheld SO2F2 gas detector multi gases analyzer HCL HCN HBR COCL2


Detection gas:HCL HCN HBR COCL2 

Range:custom

Detection Principle:Catalytic combustion / Electrochemical / Infrared

Resolution:custom

Detection Accuracy:±2%F.S

Model:HNAG920

Detection gas:HCL HCN HBR COCL2 

Range:custom

Detection Principle:Catalytic combustion / Electrochemical / Infrared

Resolution:custom

Detection Accuracy:±2%F.S

Model:HNAG920



Product Description

Portable Pumping & Diffusion Combustible Gas Detector HNAG920  is suitable for real-time and accurate detection of gas concentration and leakage in various environments, with advantages such as fast response, high measurement accuracy, excellent stability, and repeatability. It supports both pumping and diffusion modes in one unit, can be expanded to detect up to 5 gases simultaneously, and supports 4G/WiFi/Bluetooth/LoRa wireless transmission modes. The device is equipped with a built-in 2400mAh lithium battery.

Product features of Portable pump suction diffusion type combustible gas concentration detector

● Equipped with a 32-bit microprocessor and high-speed, high-precision processing circuitry for fast and accurate measurements.

● Features an external USB port for data export and deletion via USB cable connection to a computer.

● Supports up to 5 different sensors for flexible detection.

● Built-in buttons for easy parameter viewing and configuration.

● Allows unit switching (e.g., ppm ↔ mg/m³) through coefficient adjustment.

● Customizable historical data storage intervals.

● Supports Chinese/English language display switching.

● Fall alarm / one-touch emergency alarm function.

● 180° auto-rotating screen.

● Temperature & humidity compensation.

 

● PC+TPU (rubber overmolding process) for impact resistance.

 
FAQ
Q: What gases can it detect? What are the accuracy and range?

A: This depends on the instrument configuration. There are single-gas detectors (e.g., for H₂S or CO only) and multi-gas detectors (capable of simultaneously detecting 4–6 gases; common combinations include: combustible gas EX, oxygen O₂, carbon monoxide CO, and hydrogen sulfide H₂S). The range and accuracy (e.g., ±3% FS) are clearly indicated in the product manual. Confirm whether they meet your application scenario (such as confined space entry or industrial inspections) before purchasing.

Q: How accurate are the detection results? How is accuracy ensured?
A: Accuracy relies on regular calibration. New instruments are calibrated before leaving the factory, but sensors may drift during use. Calibration must be performed according to the manufacturer's requirements:
"Zero calibration": Conduct in clean air.
"Gas calibration": Use standard gas with a known concentration.
Calibration is recommended every 180 days or once a year, depending on safety regulations.
Q: What is the sensor lifespan? Are replacement costs high?
A: Sensors have a limited lifespan (typically 2–3 years for electrochemical sensors, 2–3 years for catalytic bead sensors, and longer for infrared/PID sensors). Readings become inaccurate when the sensor reaches the end of its lifespan or is damaged, requiring replacement. Sensors are the main consumable; inquire about replacement costs and ease of operation for the specific model before purchase.
Q: What should I do when the alarm activates?
A: The instrument is designed with three-level alarms (audible, visual, and vibratory) for low/high limits, TWA, and STEL. Once the alarm activates:
Immediately check the screen to confirm which gas exceeds the limit and its concentration.
Follow safety procedures: Evacuate the hazardous area immediately, moving upwind.
Report to the supervisor, and record and inspect the instrument in a safe area.
Never turn off the alarm in a hazardous area!
Q: How long does the battery last? Is charging convenient?

A: Mainstream instruments use rechargeable lithium batteries, typically offering 10–14 hours of battery life (sufficient for one shift). It is crucial to choose a charger with "explosion-proof" certification or use a safe charging dock. Some models support battery replacement for uninterrupted operation.

Portable Pumping & Diffusion Combustible Gas Detector HNAG920  is suitable for real-time and accurate detection of gas concentration and leakage in various environments, with advantages such as fast response, high measurement accuracy, excellent stability, and repeatability. It supports both pumping and diffusion modes in one unit, can be expanded to detect up to 5 gases simultaneously, and supports 4G/WiFi/Bluetooth/LoRa wireless transmission modes. The device is equipped with a built-in 2400mAh lithium battery.

Product features of Portable pump suction diffusion type combustible gas concentration detector

● Equipped with a 32-bit microprocessor and high-speed, high-precision processing circuitry for fast and accurate measurements.

● Features an external USB port for data export and deletion via USB cable connection to a computer.

● Supports up to 5 different sensors for flexible detection.

● Built-in buttons for easy parameter viewing and configuration.

● Allows unit switching (e.g., ppm ↔ mg/m³) through coefficient adjustment.

● Customizable historical data storage intervals.

● Supports Chinese/English language display switching.

● Fall alarm / one-touch emergency alarm function.

● 180° auto-rotating screen.

● Temperature & humidity compensation.

 

● PC+TPU (rubber overmolding process) for impact resistance.

 

FAQ
Q: What gases can it detect? What are the accuracy and range?
A: This depends on the instrument configuration. There are single-gas detectors (e.g., for H₂S or CO only) and multi-gas detectors (capable of simultaneously detecting 4–6 gases; common combinations include: combustible gas EX, oxygen O₂, carbon monoxide CO, and hydrogen sulfide H₂S). The range and accuracy (e.g., ±3% FS) are clearly indicated in the product manual. Confirm whether they meet your application scenario (such as confined space entry or industrial inspections) before purchasing.

 

 

Q: How accurate are the detection results? How is accuracy ensured?
A: Accuracy relies on regular calibration. New instruments are calibrated before leaving the factory, but sensors may drift during use. Calibration must be performed according to the manufacturer's requirements:
"Zero calibration": Conduct in clean air.
"Gas calibration": Use standard gas with a known concentration.
Calibration is recommended every 180 days or once a year, depending on safety regulations.

 

 

Q: What is the sensor lifespan? Are replacement costs high?
A: Sensors have a limited lifespan (typically 2–3 years for electrochemical sensors, 2–3 years for catalytic bead sensors, and longer for infrared/PID sensors). Readings become inaccurate when the sensor reaches the end of its lifespan or is damaged, requiring replacement. Sensors are the main consumable; inquire about replacement costs and ease of operation for the specific model before purchase.

 

 

Q: What should I do when the alarm activates?
A: The instrument is designed with three-level alarms (audible, visual, and vibratory) for low/high limits, TWA, and STEL. Once the alarm activates:
Immediately check the screen to confirm which gas exceeds the limit and its concentration.
Follow safety procedures: Evacuate the hazardous area immediately, moving upwind.
Report to the supervisor, and record and inspect the instrument in a safe area.
Never turn off the alarm in a hazardous area!

 

 

Q: How long does the battery last? Is charging convenient?

 

A: Mainstream instruments use rechargeable lithium batteries, typically offering 10–14 hours of battery life (sufficient for one shift). It is crucial to choose a charger with "explosion-proof" certification or use a safe charging dock. Some models support battery replacement for uninterrupted operation.
Product Recommendation
1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

47629257-f1ea-4eec-bc53-de26a94fac2e.jpeg

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument-SK/MIC-7500

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

(1).jpg

handheld helium leak detector He analyzer-HNAG900

handheld helium leak detector He analyzer

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

(2).jpg

Handheld ozone detector O3 monitor-HNAG900

Handheld ozone detector O3 monitor

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

15.jpg

handheld Hydrogen Fluoride gas detector HF-HNAG920

handheld Hydrogen Fluoride gas detector HF

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

16.jpg

Portable Ethanol analyzer C2H6O ppm-HNAG920

Portable Ethanol analyzer C2H6O ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

12-12-新款主图.jpg

Pump suction portable Ethylene gas detector C2H4 0-100ppm-HNAG920

Pump suction portable Ethylene gas detector C2H4 0-100ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Give us a free quote
Submit this form and our sales representative will contact you soon.
* Name
* Email
Phone
  • Angola+244
  • Afghanistan+93
  • Albania+355
  • Algeria+213
  • Andorra+376
  • Anguilla+1264
  • Antigua and Barbuda+1268
  • Argentina+54
  • Armenia+374
  • Ascension+247
  • Australia+61
  • Austria+43
  • Azerbaijan+994
  • Bahamas+1242
  • Bahrain+973
  • Bangladesh+880
  • Barbados+1246
  • Belarus+375
  • Belgium+32
  • Belize+501
  • Benin+229
  • Bermuda Is.+1441
  • Bolivia+591
  • Botswana+267
  • Brazil+55
  • Brunei+673
  • Bulgaria+359
  • Burkina+faso+226
  • Burma+95
  • Burundi+257
  • Cameroon+237
  • Canada+1
  • Cayman Is.+1345
  • Central African Republic+236
  • Chad+235
  • Chile+56
  • China+86
  • Colombia+57
  • Congo+242
  • Cook Is.+682
  • Costa Rica+506
  • Cuba+53
  • Cyprus+357
  • Czech Republic+420
  • Denmark+45
  • Djibouti+253
  • Dominica Rep.+1890
  • Ecuador+593
  • Egypt+20
  • EI Salvador+503
  • Estonia+372
  • Ethiopia+251
  • Fiji+679
  • Finland+358
  • France+33
  • French Guiana+594
  • Gabon+241
  • Gambia+220
  • Georgia+995
  • Germany+49
  • Ghana+233
  • Gibraltar+350
  • Greece+30
  • Grenada+1809
  • Guam+1671
  • Guatemala+502
  • Guinea+224
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hongkong+852
  • Hungary+36
  • Iceland+354
  • India+91
  • Indonesia+62
  • Iran+98
  • Iraq+964
  • Ireland+353
  • Israel+972
  • Italy+39
  • Ivory Coast+225
  • Jamaica+1876
  • Japan+81
  • Jordan+962
  • Kampuchea (Cambodia )+855
  • Kazakstan+327
  • Kenya+254
  • Korea+82
  • Kuwait+965
  • Kyrgyzstan+331
  • Laos+856
  • Latvia+371
  • Lebanon+961
  • Lesotho+266
  • Liberia+231
  • Libya+218
  • Liechtenstein+423
  • Lithuania+370
  • Luxembourg+352
  • Macao+853
  • Madagascar+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Mariana Is+1670
  • Martinique+596
  • Mauritius+230
  • Mexico+52
  • Moldova, Republic of+373
  • Monaco+377
  • Mongolia+976
  • Montserrat Is+1664
  • Morocco+212
  • Mozambique+258
  • Namibia+264
  • Nauru+674
  • Nepal+977
  • Netheriands Antilles+599
  • Netherlands+31
  • New Zealand+64
  • Nicaragua+505
  • Niger+227
  • Nigeria+234
  • North Korea+850
  • Norway+47
  • Oman+968
  • Pakistan+92
  • Panama+507
  • Papua New Cuinea+675
  • Paraguay+595
  • Peru+51
  • Philippines+63
  • Poland+48
  • French Polynesia+689
  • Portugal+351
  • Puerto Rico+1787
  • Qatar+974
  • Reunion+262
  • Romania+40
  • Russia+7
  • Saint Lueia+1758
  • Saint Vincent+1784
  • Samoa Eastern+684
  • Samoa Western+685
  • San Marino+378
  • Sao Tome and Principe+239
  • Saudi Arabia+966
  • Senegal+221
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Slovakia+421
  • Slovenia+386
  • Solomon Is+677
  • Somali+252
  • South Africa+27
  • Spain+34
  • Sri Lanka+94
  • St.Lucia+1758
  • St.Vincent+1784
  • Sudan+249
  • Suriname+597
  • Swaziland+268
  • Sweden+46
  • Switzerland+41
  • Syria+963
  • Taiwan+886
  • Tajikstan+992
  • Tanzania+255
  • Thailand+66
  • Togo+228
  • Tonga+676
  • Trinidad and Tobago+1809
  • Tunisia+216
  • Turkey+90
  • Turkmenistan+993
  • Uganda+256
  • Ukraine+380
  • United Arab Emirates+971
  • United Kiongdom+44
  • United States of America+1
  • Uruguay+598
  • Uzbekistan+233
  • Venezuela+58
  • Vietnam+84
  • Yemen+967
  • Yugoslavia+381
  • Zimbabwe+263
  • Zaire+243
  • Zambia+260
* Message