Detection gas:HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/Custom
Range:0-100ppm/Custom
Detection Principle:Catalytic combustion / Electrochemical / Infrared
Resolution:0.1ppm/Custom
Detection Accuracy:±2%F.S
Model:SK/MIC-800
Detection gas:HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/Custom
Range:0-100ppm/Custom
Detection Principle:Catalytic combustion / Electrochemical / Infrared
Resolution:0.1ppm/Custom
Detection Accuracy:±2%F.S
Model:SK/MIC-800
Portable Gas Detector Parameter Table
|
Measure gas |
CO2/EX/CH4/CO/H2S/CO2/custom |
Detection principle |
IR / Catalytic Combustion/ Electrochemistry/PID/custom |
|
range |
0-100ppm/Custom |
Resolution |
0.1ppm/Custom |
|
Sampling accuracy |
±2%F.S |
Response time |
T90<10S |
|
Working temperature |
-20 ~ 50℃ |
Working humidity |
0-95%RH |
|
Screen size |
3.5-inch LCD |
Charging interface |
5VDC |
|
Battery capacity |
5400mA |
Working air pressure |
86kpa-106kpa |
|
Working voltage |
DC5V±1%/DC24±1% |
Output method |
USB |
|
Sampling method |
Pump suction |
Warranty period |
1years |
|
External dimensions |
230×95×65mm |
Sensor service life |
1-3years |
|
Protection grade |
IP65 |
Explosion-proof grade |
Ex ib ll CT4 Gb |
|
Data storage |
100,000 entries |
Alarm record |
1000 items |
|
Alarm Settings |
The standard configuration is two-level alarm, and the alarm mode can be set: high and low alarm |
||
|
Calibration method |
Primary calibration, secondary calibration, and tertiary calibration |
||
|
Optional accessories |
High-temperature sampling handle (Customized sampling handles of different temperatures according to the detection temperature) |
||
Product features of Portable Multi Gas concentration detector
● It adopts a 32-bit microprocessor and is equipped with high-speed and high-precision processing circuits to achieve rapid and accurate measurement
● Reserve a USB interface externally. Use a USB cable to communicate with a computer to achieve data export and deletion
It can be paired with up to 6 types of sensors, providing more flexible detection
It comes with built-in buttons, allowing for easy parameter viewing, setting and other operations
By modifying the coefficients, switching between different units can be achieved, such as ppm and mg/m 3
● The storage interval for historical data can be freely set
● It has the function of switching between Chinese and English for display
Product advantages
![]() |
![]() |
![]() |
Precautions for Use
● When charging the detector, please do so in a safe place and use a 5V2A or higher charger that complies with safety regulations
● When using the detector for the first time, please fully charge the battery before use
● This detector is of pump suction type. Please do not block the air inlet and outlet of the detector to avoid clogging of the internal air pump. If the air pump fails to start after a blockage occurs, it should be shut down quickly and then restarted.
● If you need to test for a long time, please fully charge the battery first. When the battery power drops to 0%, a countdown and automatic shutdown interface will appear. You can force it to turn on, and it will automatically shut down again after 5 minutes.
● When in daily use, do not impact the detector with gas exceeding the measurement range to avoid irreversible damage.
● Do not use in harsh environments such as high temperature, high pressure or high humidity. If the humidity of the usage environment is high, filter and dehumidify before conducting the test.
● The detector should be prevented from falling from a height or being subjected to violent vibration.
● If the sensor malfunctions, please contact the after-sales service of the manufacturer.
● Under normal use, the effective service life of the sensor of the detector is 24 to 36 months. During the valid service life, the sensor should be calibrated and inspected regularly every six months or once a year (depending on the working environment) to ensure the accuracy and effectiveness of gas monitoring. Sensors that have exceeded their valid service life or are faulty must be replaced.





Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920