Category: Products Gas sensor module Aluminum alloy gas module
Key words: Products
Model: SK/MIC-500-H2
Measurement object: Hydrogen
Category: Products Gas sensor module Aluminum alloy gas module
Key words: Products
Model: SK/MIC-500-H2
Measurement object: Hydrogen
Hydrogen gas module parameters
| Output signal | RS485/4 ~-20mA (standard) customized 0.4~2.0, 0~5v, 0~10v | Operating voltage | 5v/DC24V±5% |
| Detection principle | Electrochemistry (support other principle customization) | Sampling accuracy | ±3%F.S |
| Range selection | 0-1000PPM | Resolution | 1PPM (support customization) |
| Working temperature | -20~50 ℃ | Working humidity | 0-95% RH (no condensation droplets) |
| Baud rate | 9600 | Response time | T90<10S |
| Working air pressure | 86kpa-106kpa | Service life | 1-3 years |
A discount portable H2S detector is a cost-effective solution for individuals or organizations looking to monitor hydrogen sulfide levels in various environments. These detectors are designed to be compact and lightweight, making them easy to carry and use on the go. They typically feature advanced sensor technology that provides accurate and reliable detection of H2S gas concentrations, ensuring the safety of users and preventing potential health hazards.
The cost of these discount portable H2S detectors varies depending on the brand, model, and features offered. However, they are generally more affordable than their high-end counterparts, making them accessible to a wider range of consumers. Despite their lower price point, many discount portable H2S detectors still offer essential functions such as alarms, data logging, and long battery life, providing good value for money.
When choosing a discount portable H2S detector, it is important to consider factors such as sensitivity, accuracy, ease of use, and compatibility with other safety equipment. It is also essential to purchase from reputable manufacturers and ensure that the device meets relevant safety standards and regulations. By investing in a quality discount portable H2S detector, users can effectively monitor H2S levels and take necessary precautions to protect themselves and others from harmful exposure.
Application Scenarios
Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, pharmaceutical research, pharmaceutical production workshops, tobacco companies, environmental monitoring, school research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, Garbage treatment plant, tunnel construction, oil pipeline, gas filling station, underground gas pipeline maintenance, indoor air quality inspection, safety protection in hazardous places, aerospace, military equipment monitoring, etc.
Hydrogen gas module parameters
| Output signal | RS485/4 ~-20mA (standard) customized 0.4~2.0, 0~5v, 0~10v | Operating voltage | 5v/DC24V±5% |
| Detection principle | Electrochemistry (support other principle customization) | Sampling accuracy | ±3%F.S |
| Range selection | 0-1000PPM | Resolution | 1PPM (support customization) |
| Working temperature | -20~50 ℃ | Working humidity | 0-95% RH (no condensation droplets) |
| Baud rate | 9600 | Response time | T90<10S |
| Working air pressure | 86kpa-106kpa | Service life | 1-3 years |
A discount portable H2S detector is a cost-effective solution for individuals or organizations looking to monitor hydrogen sulfide levels in various environments. These detectors are designed to be compact and lightweight, making them easy to carry and use on the go. They typically feature advanced sensor technology that provides accurate and reliable detection of H2S gas concentrations, ensuring the safety of users and preventing potential health hazards.
The cost of these discount portable H2S detectors varies depending on the brand, model, and features offered. However, they are generally more affordable than their high-end counterparts, making them accessible to a wider range of consumers. Despite their lower price point, many discount portable H2S detectors still offer essential functions such as alarms, data logging, and long battery life, providing good value for money.
When choosing a discount portable H2S detector, it is important to consider factors such as sensitivity, accuracy, ease of use, and compatibility with other safety equipment. It is also essential to purchase from reputable manufacturers and ensure that the device meets relevant safety standards and regulations. By investing in a quality discount portable H2S detector, users can effectively monitor H2S levels and take necessary precautions to protect themselves and others from harmful exposure.
Application Scenarios
Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, pharmaceutical research, pharmaceutical production workshops, tobacco companies, environmental monitoring, school research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, Garbage treatment plant, tunnel construction, oil pipeline, gas filling station, underground gas pipeline maintenance, indoor air quality inspection, safety protection in hazardous places, aerospace, military equipment monitoring, etc.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920