On-line Pre-treatment Monitoring System for Fluorine F2 Gas at the Plant Boundary of Chimney Pipeline


Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System

Key words: Products

Model: SK/MIC-7500-F2

Measurement object: Fluorine gas

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System

Key words: Products

Model: SK/MIC-7500-F2

Measurement object: Fluorine gas



Product Description

Operation process

 

The sampled gas first passes through the filter, filters dust and impurities, and then passes through the sampling pump to control the flow rate of the extracted gas through the flowmeter (the flow rate of the flowmeter is generally controlled at 0.3~0.5L/Min.), Finally, the instrument is tested (the working environment of the instrument needs to be used in the working condition of -20 ° ~ 60 °).

 

Consumables

 

The service life of the sensor is about 1 to 3 years, which is a consumable, and the specific use time is determined according to the detection environment.
2. The color of the chip inside the filter changes and needs to be replaced. The service life is about 3 months, depending on the detection environment.
3. Sampling air pump about 1 year service life

 

 

Features


1. Detector detection principle: according to the demand range customization, and can provide customized products according to user needs, without tools to achieve sensor exchange, off-line calibration and zero self-calibration
2. A variety of signal output, which can be easily connected to PLC/DCS and other industrial control systems, can also be used as a stand-alone control (switch output, RS485 output, 4-20mA output)
3. Local alarm indication, integrated sound and light detector (optional)
4. The instrument has over-range and reverse polarity protection, which can avoid the danger caused by improper operation
5. Dust filter, filter dust, when there is water, stored with peristaltic pump for discharge
6. Sampling pump, the longest sampling distance can reach 100 meters, it is recommended to be within 20 meters
7. Flow meter, control the gas flow rate, avoid the gas flow too fast to wash the sensor.



 

 

Product parameters of simple fluorine gas pretreatment on-line monitoring system

 

Output signal

① 4-20mA signal: standard 12-bit precision 4-20mA output chip, transmission distance 1Km

② RS485 signal: standard MODBUS RTU protocol, transmission distance 1Km

③ voltage signal: 0.4-2V,0-5V,0-10V output, optional (voltage output and current output two choose one)

④ Switching signal: standard 1 set of passive contact relay, capacity 220VAC3AV/24VDC3A

GPRS, 4G, WIFI, LORA, ZigBee and other wireless signals
Measuring gas fluorine gas Detection principle Electrochemistry
Range selection 0-1000PPM (more range inquiry customer service) Resolution 1PPM
Sampling accuracy ±3%F.S Response time T90<10S
Working temperature -20~50 ℃ Working humidity 0-95%RH
Storage temperature -20~50 ℃ Preheating time 10S
Working current ≤50mA Working air pressure 86kpa-106kpa
Operating voltage DC5V±1%/DC24±1% Baud rate 9600
Installation method Wall-mounted installation Pipe installation Ceiling installation Bracket installation Warranty period 1 year
Instrument size 220*205*97(L*W*H)1.5Kg Service life 1 to 3 years
Protection level IP66 waterproof splash and short time rain Explosion-proof grade E x d I IC T 6
Receiving equipment User computer, control alarm, PLC, DCS, DDC, etc.
Alarm mode On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc.
Alarm Settings Standard configuration of two-level alarm, optional three-level alarm; alarm mode can be set: regular high and low alarm, interval control alarm
Connection cable

① Select three-core shielded cable for 4 ~ 20mA and four-core cable for RS485. When the distance exceeds 1000 m (with a detector), the single wire diameter shall be ≥ 1.5mm, and the shielding layer shall be connected to the ground.

② wireless transmission: can be built-in LORA, Zigbeg module, short-range wireless transmission; external GPRS/4G module, remote data transmission to the cloud platform, can be viewed on the computer side and mobile phone side of the history, not limited by distance (optional)

Optional accessories

Normal temperature and high humidity pretreatment system, high temperature and normal humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system, pressure reducing valve, flow meter, chloroform gas measurement, 24VDC or 220AC sampling pump (sampling distance is 10 meters), vacuum pump (sampling distance is more than 40 meters), 24V switching power supply, 220V to 24V power adapter.

Computer monitoring accessories: free upper computer software, USB to RS485 conversion cable, RS485 to network port converter if network transmission is required.

Mounting bracket

 

 

Ordinary stainless steel box can be customized explosion-proof box

 

Application Scenarios


Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, pharmaceutical research, pharmaceutical production workshops, tobacco companies, environmental monitoring, school research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, Garbage treatment plant, tunnel construction, oil pipeline, gas filling station, underground gas pipeline maintenance, indoor air quality inspection, safety protection in hazardous places, aerospace, military equipment monitoring, etc.

 

 

On-line fluorine gas concentration detector interface display introduction

The instrument has a total of 3 buttons, namely "add/cancel", "function/confirm", "move right/down" (hereinafter referred to as "add" ("cancel"), "function" ("confirm"), "move right" ("move left")). The three key positions are as follows. Press the "Function" button.

 

Internal diagram of online fluorine gas concentration detector

 

On-line fluorine gas concentration detector can be used stand-alone

or connectionManagement control machine with the use of wiring diagram

4-20mA Wiring Definition Chart RS485 Wiring Definition Chart

 

Can be configured according to the needs of the seven-inch LCD touch screen

 

Pipe Description


There are 4 pipe connections:
One sampling air inlet;
2 water outlets, with a throttle valve on the water outlet, which is usually tightened and normally closed. Check regularly. If there is water in the water outlet pipeline, water can be discharged through the valve;
1 air outlet;

 

Operation process

 

The sampled gas first passes through the filter, filters dust and impurities, and then passes through the sampling pump to control the flow rate of the extracted gas through the flowmeter (the flow rate of the flowmeter is generally controlled at 0.3~0.5L/Min.), Finally, the instrument is tested (the working environment of the instrument needs to be used in the working condition of -20 ° ~ 60 °).

 

Consumables

 

The service life of the sensor is about 1 to 3 years, which is a consumable, and the specific use time is determined according to the detection environment.
2. The color of the chip inside the filter changes and needs to be replaced. The service life is about 3 months, depending on the detection environment.
3. Sampling air pump about 1 year service life

 

 

Features


1. Detector detection principle: according to the demand range customization, and can provide customized products according to user needs, without tools to achieve sensor exchange, off-line calibration and zero self-calibration
2. A variety of signal output, which can be easily connected to PLC/DCS and other industrial control systems, can also be used as a stand-alone control (switch output, RS485 output, 4-20mA output)
3. Local alarm indication, integrated sound and light detector (optional)
4. The instrument has over-range and reverse polarity protection, which can avoid the danger caused by improper operation
5. Dust filter, filter dust, when there is water, stored with peristaltic pump for discharge
6. Sampling pump, the longest sampling distance can reach 100 meters, it is recommended to be within 20 meters
7. Flow meter, control the gas flow rate, avoid the gas flow too fast to wash the sensor.



 

 

Product parameters of simple fluorine gas pretreatment on-line monitoring system

 

Output signal

① 4-20mA signal: standard 12-bit precision 4-20mA output chip, transmission distance 1Km

② RS485 signal: standard MODBUS RTU protocol, transmission distance 1Km

③ voltage signal: 0.4-2V,0-5V,0-10V output, optional (voltage output and current output two choose one)

④ Switching signal: standard 1 set of passive contact relay, capacity 220VAC3AV/24VDC3A

GPRS, 4G, WIFI, LORA, ZigBee and other wireless signals
Measuring gas fluorine gas Detection principle Electrochemistry
Range selection 0-1000PPM (more range inquiry customer service) Resolution 1PPM
Sampling accuracy ±3%F.S Response time T90<10S
Working temperature -20~50 ℃ Working humidity 0-95%RH
Storage temperature -20~50 ℃ Preheating time 10S
Working current ≤50mA Working air pressure 86kpa-106kpa
Operating voltage DC5V±1%/DC24±1% Baud rate 9600
Installation method Wall-mounted installation Pipe installation Ceiling installation Bracket installation Warranty period 1 year
Instrument size 220*205*97(L*W*H)1.5Kg Service life 1 to 3 years
Protection level IP66 waterproof splash and short time rain Explosion-proof grade E x d I IC T 6
Receiving equipment User computer, control alarm, PLC, DCS, DDC, etc.
Alarm mode On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc.
Alarm Settings Standard configuration of two-level alarm, optional three-level alarm; alarm mode can be set: regular high and low alarm, interval control alarm
Connection cable

① Select three-core shielded cable for 4 ~ 20mA and four-core cable for RS485. When the distance exceeds 1000 m (with a detector), the single wire diameter shall be ≥ 1.5mm, and the shielding layer shall be connected to the ground.

② wireless transmission: can be built-in LORA, Zigbeg module, short-range wireless transmission; external GPRS/4G module, remote data transmission to the cloud platform, can be viewed on the computer side and mobile phone side of the history, not limited by distance (optional)

Optional accessories

Normal temperature and high humidity pretreatment system, high temperature and normal humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system, pressure reducing valve, flow meter, chloroform gas measurement, 24VDC or 220AC sampling pump (sampling distance is 10 meters), vacuum pump (sampling distance is more than 40 meters), 24V switching power supply, 220V to 24V power adapter.

Computer monitoring accessories: free upper computer software, USB to RS485 conversion cable, RS485 to network port converter if network transmission is required.

Mounting bracket

 

 

Ordinary stainless steel box can be customized explosion-proof box

 

Application Scenarios


Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, pharmaceutical research, pharmaceutical production workshops, tobacco companies, environmental monitoring, school research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, Garbage treatment plant, tunnel construction, oil pipeline, gas filling station, underground gas pipeline maintenance, indoor air quality inspection, safety protection in hazardous places, aerospace, military equipment monitoring, etc.

 

 

On-line fluorine gas concentration detector interface display introduction

The instrument has a total of 3 buttons, namely "add/cancel", "function/confirm", "move right/down" (hereinafter referred to as "add" ("cancel"), "function" ("confirm"), "move right" ("move left")). The three key positions are as follows. Press the "Function" button.

 

Internal diagram of online fluorine gas concentration detector

 

On-line fluorine gas concentration detector can be used stand-alone

or connectionManagement control machine with the use of wiring diagram

4-20mA Wiring Definition Chart RS485 Wiring Definition Chart

 

Can be configured according to the needs of the seven-inch LCD touch screen

 

Pipe Description


There are 4 pipe connections:
One sampling air inlet;
2 water outlets, with a throttle valve on the water outlet, which is usually tightened and normally closed. Check regularly. If there is water in the water outlet pipeline, water can be discharged through the valve;
1 air outlet;

 

Product Recommendation
1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

47629257-f1ea-4eec-bc53-de26a94fac2e.jpeg

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument-SK/MIC-7500

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

(1).jpg

handheld helium leak detector He analyzer-HNAG900

handheld helium leak detector He analyzer

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

(2).jpg

Handheld ozone detector O3 monitor-HNAG900

Handheld ozone detector O3 monitor

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

15.jpg

handheld Hydrogen Fluoride gas detector HF-HNAG920

handheld Hydrogen Fluoride gas detector HF

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

16.jpg

Portable Ethanol analyzer C2H6O ppm-HNAG920

Portable Ethanol analyzer C2H6O ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

12-12-新款主图.jpg

Pump suction portable Ethylene gas detector C2H4 0-100ppm-HNAG920

Pump suction portable Ethylene gas detector C2H4 0-100ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Give us a free quote
Submit this form and our sales representative will contact you soon.
* Name
* Email
Phone
  • Angola+244
  • Afghanistan+93
  • Albania+355
  • Algeria+213
  • Andorra+376
  • Anguilla+1264
  • Antigua and Barbuda+1268
  • Argentina+54
  • Armenia+374
  • Ascension+247
  • Australia+61
  • Austria+43
  • Azerbaijan+994
  • Bahamas+1242
  • Bahrain+973
  • Bangladesh+880
  • Barbados+1246
  • Belarus+375
  • Belgium+32
  • Belize+501
  • Benin+229
  • Bermuda Is.+1441
  • Bolivia+591
  • Botswana+267
  • Brazil+55
  • Brunei+673
  • Bulgaria+359
  • Burkina+faso+226
  • Burma+95
  • Burundi+257
  • Cameroon+237
  • Canada+1
  • Cayman Is.+1345
  • Central African Republic+236
  • Chad+235
  • Chile+56
  • China+86
  • Colombia+57
  • Congo+242
  • Cook Is.+682
  • Costa Rica+506
  • Cuba+53
  • Cyprus+357
  • Czech Republic+420
  • Denmark+45
  • Djibouti+253
  • Dominica Rep.+1890
  • Ecuador+593
  • Egypt+20
  • EI Salvador+503
  • Estonia+372
  • Ethiopia+251
  • Fiji+679
  • Finland+358
  • France+33
  • French Guiana+594
  • Gabon+241
  • Gambia+220
  • Georgia+995
  • Germany+49
  • Ghana+233
  • Gibraltar+350
  • Greece+30
  • Grenada+1809
  • Guam+1671
  • Guatemala+502
  • Guinea+224
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hongkong+852
  • Hungary+36
  • Iceland+354
  • India+91
  • Indonesia+62
  • Iran+98
  • Iraq+964
  • Ireland+353
  • Israel+972
  • Italy+39
  • Ivory Coast+225
  • Jamaica+1876
  • Japan+81
  • Jordan+962
  • Kampuchea (Cambodia )+855
  • Kazakstan+327
  • Kenya+254
  • Korea+82
  • Kuwait+965
  • Kyrgyzstan+331
  • Laos+856
  • Latvia+371
  • Lebanon+961
  • Lesotho+266
  • Liberia+231
  • Libya+218
  • Liechtenstein+423
  • Lithuania+370
  • Luxembourg+352
  • Macao+853
  • Madagascar+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Mariana Is+1670
  • Martinique+596
  • Mauritius+230
  • Mexico+52
  • Moldova, Republic of+373
  • Monaco+377
  • Mongolia+976
  • Montserrat Is+1664
  • Morocco+212
  • Mozambique+258
  • Namibia+264
  • Nauru+674
  • Nepal+977
  • Netheriands Antilles+599
  • Netherlands+31
  • New Zealand+64
  • Nicaragua+505
  • Niger+227
  • Nigeria+234
  • North Korea+850
  • Norway+47
  • Oman+968
  • Pakistan+92
  • Panama+507
  • Papua New Cuinea+675
  • Paraguay+595
  • Peru+51
  • Philippines+63
  • Poland+48
  • French Polynesia+689
  • Portugal+351
  • Puerto Rico+1787
  • Qatar+974
  • Reunion+262
  • Romania+40
  • Russia+7
  • Saint Lueia+1758
  • Saint Vincent+1784
  • Samoa Eastern+684
  • Samoa Western+685
  • San Marino+378
  • Sao Tome and Principe+239
  • Saudi Arabia+966
  • Senegal+221
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Slovakia+421
  • Slovenia+386
  • Solomon Is+677
  • Somali+252
  • South Africa+27
  • Spain+34
  • Sri Lanka+94
  • St.Lucia+1758
  • St.Vincent+1784
  • Sudan+249
  • Suriname+597
  • Swaziland+268
  • Sweden+46
  • Switzerland+41
  • Syria+963
  • Taiwan+886
  • Tajikstan+992
  • Tanzania+255
  • Thailand+66
  • Togo+228
  • Tonga+676
  • Trinidad and Tobago+1809
  • Tunisia+216
  • Turkey+90
  • Turkmenistan+993
  • Uganda+256
  • Ukraine+380
  • United Arab Emirates+971
  • United Kiongdom+44
  • United States of America+1
  • Uruguay+598
  • Uzbekistan+233
  • Venezuela+58
  • Vietnam+84
  • Yemen+967
  • Yugoslavia+381
  • Zimbabwe+263
  • Zaire+243
  • Zambia+260
* Message