Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System
Key words: Products
Model: SK/MIC-7500-CL2
Measurement object: Chlorine
Operation process
The sampled gas first passes through the filter, filters dust and impurities, and then passes through the sampling pump to control the flow rate of the extracted gas through the flowmeter (the flow rate of the flowmeter is generally controlled at 0.3~0.5L/Min.), Finally, the instrument is tested (the working environment of the instrument needs to be used in the working condition of -20 ° ~ 60 °).
Consumables
The service life of the sensor is about 1 to 3 years, which is a consumable, and the specific use time is determined according to the detection environment.
2. The color of the chip inside the filter changes and needs to be replaced. The service life is about 3 months, depending on the detection environment.
3. Sampling air pump about 1 year service life
Features
1. Detector detection principle: according to the demand range customization, and can provide customized products according to user needs, without tools to achieve sensor exchange, off-line calibration and zero self-calibration
2. A variety of signal output, which can be easily connected to PLC/DCS and other industrial control systems, can also be used as a stand-alone control (switch output, RS485 output, 4-20mA output)
3. Local alarm indication, integrated sound and light detector (optional)
4. The instrument has over-range and reverse polarity protection, which can avoid the danger caused by improper operation
5. Dust filter, filter dust, when there is water, stored with peristaltic pump for discharge
6. Sampling pump, the longest sampling distance can reach 100 meters, it is recommended to be within 20 meters
7. Flow meter, control the gas flow rate, avoid the gas flow too fast to wash the sensor.
| Output signal |
① 4-20mA signal: standard 12-bit precision 4-20mA output chip, transmission distance 1Km ② RS485 signal: standard MODBUS RTU protocol, transmission distance 1Km ③ voltage signal: 0.4-2V,0-5V,0-10V output, optional (voltage output and current output two choose one) ④ Switching signal: standard 1 set of passive contact relay, capacity 220VAC3AV/24VDC3A |
GPRS, 4G, WIFI, LORA, ZigBee and other wireless signals | |
| Measuring gas | Chlorine gas | Detection principle | catalytic combustion/infrared NDIR/semiconductor/thermal conductivity |
| Range selection | 0-100PPM (more range inquiry customer service) | Resolution | 0.1PPM |
| Sampling accuracy | ±3%F.S | Response time | T90<10S |
| Working temperature | -20~50 ℃ | Working humidity | 0-95%RH |
| Storage temperature | -20~50 ℃ | Preheating time | 10S |
| Working current | ≤50mA | Working air pressure | 86kpa-106kpa |
| Operating voltage | DC5V±1%/DC24±1% | Baud rate | 9600 |
| Installation method | Wall-mounted installation Pipe installation Ceiling installation Bracket installation | Warranty period | 1 year |
| Instrument size | 220*205*97(L*W*H)1.5Kg | Service life | 1 to 3 years |
| Protection level | IP66 waterproof splash and short time rain | Explosion-proof grade | E x d I IC T 6 |
| Receiving equipment | User computer, control alarm, PLC, DCS, DDC, etc. | ||
| Alarm mode | On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc. | ||
| Alarm Settings | Standard configuration of two-level alarm, optional three-level alarm; alarm mode can be set: regular high and low alarm, interval control alarm | ||
| Connection cable |
① Select three-core shielded cable for 4 ~ 20mA and four-core cable for RS485. When the distance exceeds 1000 m (with a detector), the single wire diameter shall be ≥ 1.5mm, and the shielding layer shall be connected to the ground. ② wireless transmission: can be built-in LORA, Zigbeg module, short-range wireless transmission; external GPRS/4G module, remote data transmission to the cloud platform, can be viewed on the computer side and mobile phone side of the history, not limited by distance (optional) |
||
| Optional accessories |
Normal temperature and high humidity pretreatment system, high temperature and normal humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system, pressure reducing valve, flow meter, chloroform gas measurement, 24VDC or 220AC sampling pump (sampling distance is 10 meters), vacuum pump (sampling distance is more than 40 meters), 24V switching power supply, 220V to 24V power adapter. Computer monitoring accessories: free upper computer software, USB to RS485 conversion cable, RS485 to network port converter if network transmission is required. Mounting bracket |
||
Ordinary stainless steel box can be customized explosion-proof box
![]() |
![]() |
Application Scenarios
Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, pharmaceutical research, pharmaceutical production workshops, tobacco companies, environmental monitoring, school research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, Garbage treatment plant, tunnel construction, oil pipeline, gas filling station, underground gas pipeline maintenance, indoor air quality inspection, safety protection in hazardous places, aerospace, military equipment monitoring, etc.
On-line chlorine gas concentration detector interface display introduction

The instrument has a total of 3 buttons, namely "add/cancel", "function/confirm", "move right/down" (hereinafter referred to as "add" ("cancel"), "function" ("confirm"), "move right" ("move left")). The three key positions are as follows. Press the "Function" button.
Internal diagram of online chlorine gas concentration detector


On-line chlorine gas concentration detector can be used stand-alone
or connectionManagement control machine with the use of wiring diagram
| 4-20mA Wiring Definition Chart | RS485 Wiring Definition Chart |
![]() |
![]() |
Can be configured according to the needs of the seven-inch LCD touch screen

Pipe Description
There are 4 pipe connections:
One sampling air inlet;
2 water outlets, with a throttle valve on the water outlet, which is usually tightened and normally closed. Check regularly. If there is water in the water outlet pipeline, water can be discharged through the valve;
1 air outlet;



This professional portable H2O2 hydrogen peroxide single gas detector supports pump suction & dual diffusion sampling, with 180° auto-rotating color screen, 4G/WiFi/Bluetooth/LORA multi connectivity. It stores up to 120,000 historical records, features multi-level alarm, wide optional H2O2 ranges, USB Type-C charging & data export, ideal for industrial H2O2 leakage monitoring.

HNAG920-C2H6O is a professional portable single ethanol C2H6O gas detector with dual pump suction & diffusion sampling modes. It features auto 180° rotating color screen, one-touch emergency alarm, Type-C 2-in-1 charge & data export, max 120,000 data logs, optional 4G/WiFi/Bluetooth/LoRa. Multiple ethanol measuring ranges available, explosion-proof Ex certification for factory, laboratory & alcohol workshop safety monitoring.

Discover the Combustible Online Gas Detector LEL Alarm Monitor System. This advanced system is designed for real - time detection of combustible gases. It offers high - precision monitoring, rapid alarm response to ensure safety in environments with potential gas hazards. Ideal for industrial settings, it helps prevent gas - related accidents and provides reliable data for better management.

This HNAG920-C2H4 portable ethylene (C2H4) single gas detector adopts pump suction & diffusion dual sampling design, with 180° auto-rotating color screen. It supports 4G/WiFi/Bluetooth/LORA multi wireless modes, mobile viewing & Bluetooth printing, stores 120,000 historical records. It has multi-level audible-visual alarm, IP rugged housing, multiple optional measuring ranges for industrial ethylene leakage detection.

Secure your facility with Skyeaglee's split-type helium and argon gas detector. Features thermal conductivity sensing, ranges up to 100%vol, IP66 rating, and real-time monitoring.

Portable HNAG920-SF6 single gas detector for sulfur hexafluoride leakage detection, measuring range optional 0-1000/2000/3000/5000ppm. Adopts high precision sensor, with auto screen rotation, multi-alarm system, 120,000 historical data logs, support WiFi/Bluetooth/LoRa/4G wireless transmission, CE, Ex, SIL3 certified for power substation electrical equipment SF6 leak inspection.

This HNAG920-CS2 portable carbon disulfide gas detector supports multiple CS2 measuring ranges from 0-20ppm to 0-10000ppm. It adopts advanced sensing principle, features auto screen rotation, dual pump/diffusion sampling, 120,000 historical data logs, multi wireless transmission, Type-C 2-in-1 charging & data transfer, visual & audible multi-alarm, rugged PC+TPU housing for industrial hazardous scenarios.

This HNAG920-NH3 handheld single ammonia gas detector provides 12 optional NH3 measuring ranges from 0-10ppm up to 0-100%Vol. It supports auto 180° screen rotation, 4G/WiFi/Bluetooth/LORA wireless transmission, Type-C rechargeable design, 4-side LED alarm lights, durable PC+TPU housing, and allows mobile data viewing & Bluetooth printing for chemical plants, livestock farms and refrigeration workshop hazardous gas monitoring.

Skyeaglee HANG-900-CH4-C portable methane gas detector with catalytic detection 0-100%LEL, IP65, Ex ib II CT4 Gb. Expandable to 6 gases, 5400mAh, USB data export. Professional methane gas monitor for oil, coal, petrochemical.

Explore the Portable pump - assisted diffusion - type hydrogen gas detector. This detector combines pump - assisted and diffusion - type features, offering high - precision hydrogen detection.

The HNAG1000-PM is an industrial fixed dust detector featuring a high-precision laser scattering sensor. With IP66 protection, explosion-proof casing, and RS485/4-20mA outputs, it ensures real-time, accurate PM monitoring for harsh environments.

Engineered for hazardous industrial sites, the HNAG1000-PM-M provides continuous online particulate matter monitoring. With an IP66 rugged enclosure, ExdIICT6 certification, and seamless PLC integration via RS485/4-20mA, it guarantees absolute safety.

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

HNAG900-NH3 portable ammonia gas detector adopts imported Honeywell sensor with pump suction design. It supports multiple optional NH3 measuring ranges, equips flexible sampling probe, multi-mode data transmission including 4/5G, LoRa and Bluetooth, supports local data storage & USB export, ideal for industrial leak check, indoor air monitoring and on-site environmental testing.

This HNAG900 handheld H2S hydrogen sulfide gas detector adopts imported sensor, 0-10ppm measuring range, built-in vacuum suction pump. It supports real-time curve display, USB data export, optional 4/5G, LoRa and Bluetooth transmission, equipped with bendable sampling probe, long-life battery, widely used for industrial leak check, indoor air quality inspection and on-site environmental gas testing.

HNAG900 portable CO carbon monoxide gas detector supports multiple measurement ranges for atmospheric & industrial gas monitoring. Equipped with imported Honeywell sensor, built-in vacuum suction pump, 27cm bendable sampling probe. It supports USB data export, 4/5G, LoRa, Bluetooth transmission, with large data storage, audible alarm, stable performance for factory leak check, ambient air inspection and industrial safety detection.

This pump-type portable CH4 methane detector equips Honeywell high precision sensor, supports multiple measuring ranges for methane testing. It adopts color LCD curve display, supports 4/5G cloud upload, LoRa and Bluetooth transmission for remote viewing, onsite printing and USB data export. 5400mA large battery offers long runtime, optional high/normal temperature probes, ideal for industrial methane leak check, environmental testing and indoor gas monitoring.

This portable pump-suction CO2 gas detector adopts imported Honeywell sensor, supports multiple measuring ranges for CO2 detection. Equipped with color LCD trend display, 4/5G, LoRa P2P and Bluetooth data transmission, it supports mobile/PC remote viewing, Bluetooth printing and USB data export. 5400mA large battery ensures long operation time, optional high/normal temperature sampling probes, widely used for indoor air test, industrial leak inspection, environmental monitoring.

This portable CH2O formaldehyde single gas detector adopts high-precision electrochemical sensor, supports pump suction & dual diffusion sampling, 180° auto screen rotation, 120,000 historical data storage, Type-C charging & data export, multiple wireless transmission modes, audible-visual alarm, IP rugged housing, widely used in indoor decoration, factory workshop, industrial environmental formaldehyde concentration detection.

This professional portable H2SO4 sulfuric acid single gas detector supports 0-30mg/m³ & 0-300mg/m³ measuring ranges, with pump suction & dual diffusion sampling modes, auto 180° screen rotation, multi-alarm design, 120,000 historical data storage, 4G/WiFi/Bluetooth/LORA connectivity, IP-grade rugged PC+TPU housing, ideal for chemical plant, lab and industrial toxic gas monitoring scenarios.

This professional portable H2O2 hydrogen peroxide single gas detector supports pump suction & dual diffusion sampling, with 180° auto-rotating color screen, 4G/WiFi/Bluetooth/LORA multi connectivity. It stores up to 120,000 historical records, features multi-level alarm, wide optional H2O2 ranges, USB Type-C charging & data export, ideal for industrial H2O2 leakage monitoring.

HNAG920-C2H6O is a professional portable single ethanol C2H6O gas detector with dual pump suction & diffusion sampling modes. It features auto 180° rotating color screen, one-touch emergency alarm, Type-C 2-in-1 charge & data export, max 120,000 data logs, optional 4G/WiFi/Bluetooth/LoRa. Multiple ethanol measuring ranges available, explosion-proof Ex certification for factory, laboratory & alcohol workshop safety monitoring.

Discover the Combustible Online Gas Detector LEL Alarm Monitor System. This advanced system is designed for real - time detection of combustible gases. It offers high - precision monitoring, rapid alarm response to ensure safety in environments with potential gas hazards. Ideal for industrial settings, it helps prevent gas - related accidents and provides reliable data for better management.

This HNAG920-C2H4 portable ethylene (C2H4) single gas detector adopts pump suction & diffusion dual sampling design, with 180° auto-rotating color screen. It supports 4G/WiFi/Bluetooth/LORA multi wireless modes, mobile viewing & Bluetooth printing, stores 120,000 historical records. It has multi-level audible-visual alarm, IP rugged housing, multiple optional measuring ranges for industrial ethylene leakage detection.

Secure your facility with Skyeaglee's split-type helium and argon gas detector. Features thermal conductivity sensing, ranges up to 100%vol, IP66 rating, and real-time monitoring.

Portable HNAG920-SF6 single gas detector for sulfur hexafluoride leakage detection, measuring range optional 0-1000/2000/3000/5000ppm. Adopts high precision sensor, with auto screen rotation, multi-alarm system, 120,000 historical data logs, support WiFi/Bluetooth/LoRa/4G wireless transmission, CE, Ex, SIL3 certified for power substation electrical equipment SF6 leak inspection.

This HNAG920-CS2 portable carbon disulfide gas detector supports multiple CS2 measuring ranges from 0-20ppm to 0-10000ppm. It adopts advanced sensing principle, features auto screen rotation, dual pump/diffusion sampling, 120,000 historical data logs, multi wireless transmission, Type-C 2-in-1 charging & data transfer, visual & audible multi-alarm, rugged PC+TPU housing for industrial hazardous scenarios.

This HNAG920-NH3 handheld single ammonia gas detector provides 12 optional NH3 measuring ranges from 0-10ppm up to 0-100%Vol. It supports auto 180° screen rotation, 4G/WiFi/Bluetooth/LORA wireless transmission, Type-C rechargeable design, 4-side LED alarm lights, durable PC+TPU housing, and allows mobile data viewing & Bluetooth printing for chemical plants, livestock farms and refrigeration workshop hazardous gas monitoring.

Skyeaglee HANG-900-CH4-C portable methane gas detector with catalytic detection 0-100%LEL, IP65, Ex ib II CT4 Gb. Expandable to 6 gases, 5400mAh, USB data export. Professional methane gas monitor for oil, coal, petrochemical.

Explore the Portable pump - assisted diffusion - type hydrogen gas detector. This detector combines pump - assisted and diffusion - type features, offering high - precision hydrogen detection.

The HNAG1000-PM is an industrial fixed dust detector featuring a high-precision laser scattering sensor. With IP66 protection, explosion-proof casing, and RS485/4-20mA outputs, it ensures real-time, accurate PM monitoring for harsh environments.

Engineered for hazardous industrial sites, the HNAG1000-PM-M provides continuous online particulate matter monitoring. With an IP66 rugged enclosure, ExdIICT6 certification, and seamless PLC integration via RS485/4-20mA, it guarantees absolute safety.

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

HNAG900-NH3 portable ammonia gas detector adopts imported Honeywell sensor with pump suction design. It supports multiple optional NH3 measuring ranges, equips flexible sampling probe, multi-mode data transmission including 4/5G, LoRa and Bluetooth, supports local data storage & USB export, ideal for industrial leak check, indoor air monitoring and on-site environmental testing.