Detection gas:H2S/hydrogen sulfide

Range:0-100ppm/Custom

Detection Principle:Electrochemistry

Resolution:0.1ppm

Detection Accuracy:±3%F.S

Model:SK/MIC-500

Detection gas:H2S/hydrogen sulfide

Range:0-100ppm/Custom

Detection Principle:Electrochemistry

Resolution:0.1ppm

Detection Accuracy:±3%F.S

Model:SK/MIC-500



Product Description

1. Ultra-Compact Industrial Design for Flexible Integration

With an external dimension of just diameter 48mm × height 95mm​ (excluding pins) and a standard M20 * 1.5 external thread​ for mounting, this module is exceptionally compact and lightweight. This makes it perfectly suited for integration into space-constrained designs, such as portable H2S detector​ units and handheld gas leak detector​ tools, without compromising on robustness due to its ABS/aluminum alloy​ housing.

2. Multi-Principle, High-Performance Sensing Platform

The module supports a selectable ("Optional") measurement gas and detection principle. It is designed to professionally integrate high-quality sensors, including electrochemical (ideal for H2S gas), catalytic combustion, infrared, thermal conductivity, and PID types. This flexibility allows it to serve as the sensing core for a precise hydrogen sulfide monitor​ or other specific gas sensor detector​ applications.

3. High Accuracy, Rapid Response, and Long-Term Stability

Engineered for dependable performance, the module guarantees a sampling accuracy of ±3% F.S.​ and repeatability of ±1% F.S.​ It delivers a fast response time (T90) of <30 seconds​ with a short 10-second preheat time, ensuring quick and reliable threat detection. Its exceptional long-term drift of ≤±1% F.S. per year​ ensures stable readings over its 2~3 year service life, which is critical for maintaining the reliability of any H2S alarm​ system.

4. Intelligent Features for Simplified Operation & Maintenance

The module simplifies setup and upkeep. It features factory-precise calibration​ for true plug-and-play operation and includes a data recovery function​ to safeguard against operational errors. Users can perform zero-point fine-tuning​ and connect directly to a computer for self-calibration, facilitating easy maintenance. Its output interface combines RS-485 digital communication with a selectable 4~20mA analog current, providing maximum flexibility for system debugging and integration.

5. Low-Power, Rugged Construction for Demanding Applications

Consuming a low operating current of ≤50mA​ from a 12-24V DC​ source, it is highly suitable for portable, battery-powered devices like portable H2S detector​ units. It operates reliably in harsh conditions, within a temperature range of -20°C to 50°C​ and humidity of 0-95% RH (non-condensing), making it an excellent choice for environmental monitoring, drone-based atmospheric sampling, and fixed industrial hydrogen sulfide detection​ systems.

FAQ:

1. Q: Can this module be used as the core sensor for a portable H2S gas detector?

A:​ Absolutely. Its compact size (Φ48mm x 95mm), low power consumption (≤50mA), and robust construction make it an ideal, high-performance sensing core for building reliable and durable portable H2S detector​ tools.

2. Q: What level of accuracy can I expect for hydrogen sulfide monitoring with this module?

A:​ When configured with an electrochemical sensor for H2S gas, the module delivers highly accurate and stable readings, with a sampling accuracy of ±3% F.S.​ and minimal long-term drift (≤±1% F.S./year), ensuring your hydrogen sulfide gas detector​ provides trustworthy data over time.

3. Q: How does the output configuration aid in building a complete gas detector system?

A:​ The dual RS-485 + 4~20mA output interface​ offers maximum integration flexibility. The 4~20mA signal can connect directly to PLCs or controllers, while the RS-485 allows for networked communication with multiple sensors, simplifying the design of complex gas detector​ systems.

1. Ultra-Compact Industrial Design for Flexible Integration

With an external dimension of just diameter 48mm × height 95mm​ (excluding pins) and a standard M20 * 1.5 external thread​ for mounting, this module is exceptionally compact and lightweight. This makes it perfectly suited for integration into space-constrained designs, such as portable H2S detector​ units and handheld gas leak detector​ tools, without compromising on robustness due to its ABS/aluminum alloy​ housing.

2. Multi-Principle, High-Performance Sensing Platform

The module supports a selectable ("Optional") measurement gas and detection principle. It is designed to professionally integrate high-quality sensors, including electrochemical (ideal for H2S gas), catalytic combustion, infrared, thermal conductivity, and PID types. This flexibility allows it to serve as the sensing core for a precise hydrogen sulfide monitor​ or other specific gas sensor detector​ applications.

3. High Accuracy, Rapid Response, and Long-Term Stability

Engineered for dependable performance, the module guarantees a sampling accuracy of ±3% F.S.​ and repeatability of ±1% F.S.​ It delivers a fast response time (T90) of <30 seconds​ with a short 10-second preheat time, ensuring quick and reliable threat detection. Its exceptional long-term drift of ≤±1% F.S. per year​ ensures stable readings over its 2~3 year service life, which is critical for maintaining the reliability of any H2S alarm​ system.

4. Intelligent Features for Simplified Operation & Maintenance

The module simplifies setup and upkeep. It features factory-precise calibration​ for true plug-and-play operation and includes a data recovery function​ to safeguard against operational errors. Users can perform zero-point fine-tuning​ and connect directly to a computer for self-calibration, facilitating easy maintenance. Its output interface combines RS-485 digital communication with a selectable 4~20mA analog current, providing maximum flexibility for system debugging and integration.

5. Low-Power, Rugged Construction for Demanding Applications

Consuming a low operating current of ≤50mA​ from a 12-24V DC​ source, it is highly suitable for portable, battery-powered devices like portable H2S detector​ units. It operates reliably in harsh conditions, within a temperature range of -20°C to 50°C​ and humidity of 0-95% RH (non-condensing), making it an excellent choice for environmental monitoring, drone-based atmospheric sampling, and fixed industrial hydrogen sulfide detection​ systems.

FAQ:

1. Q: Can this module be used as the core sensor for a portable H2S gas detector?

A:​ Absolutely. Its compact size (Φ48mm x 95mm), low power consumption (≤50mA), and robust construction make it an ideal, high-performance sensing core for building reliable and durable portable H2S detector​ tools.

2. Q: What level of accuracy can I expect for hydrogen sulfide monitoring with this module?

A:​ When configured with an electrochemical sensor for H2S gas, the module delivers highly accurate and stable readings, with a sampling accuracy of ±3% F.S.​ and minimal long-term drift (≤±1% F.S./year), ensuring your hydrogen sulfide gas detector​ provides trustworthy data over time.

3. Q: How does the output configuration aid in building a complete gas detector system?

A:​ The dual RS-485 + 4~20mA output interface​ offers maximum integration flexibility. The 4~20mA signal can connect directly to PLCs or controllers, while the RS-485 allows for networked communication with multiple sensors, simplifying the design of complex gas detector​ systems.

Product Recommendation
1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

47629257-f1ea-4eec-bc53-de26a94fac2e.jpeg

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument-SK/MIC-7500

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

(1).jpg

handheld helium leak detector He analyzer-HNAG900

handheld helium leak detector He analyzer

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

(2).jpg

Handheld ozone detector O3 monitor-HNAG900

Handheld ozone detector O3 monitor

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

15.jpg

handheld Hydrogen Fluoride gas detector HF-HNAG920

handheld Hydrogen Fluoride gas detector HF

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

16.jpg

Portable Ethanol analyzer C2H6O ppm-HNAG920

Portable Ethanol analyzer C2H6O ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

12-12-新款主图.jpg

Pump suction portable Ethylene gas detector C2H4 0-100ppm-HNAG920

Pump suction portable Ethylene gas detector C2H4 0-100ppm

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

1.jpg

Portable SF6 gas analyzer Sulfur hexafluoride detector-HNAG920

Portable SF6 gas analyzer Sulfur hexafluoride detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

2.jpg

Handheld Acetylene gas detector 0-100%LEL-HNAG920

Handheld Acetylene gas detector 0-100%LEL

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

3.jpg

Portable Methyl Bromide Gas Detector CH3Br-HNAG920

Portable Methyl Bromide Gas Detector CH3Br

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

1.jpg

Punp suction Portable ozone sensor detector-HNAG920

Punp suction Portable ozone sensor detector

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

(4).jpg

Handheld SF6 gas detector Sulfur hexafluoride analyzer-HNAG900

Handheld SF6 gas detector Sulfur hexafluoride analyzer

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

(9).jpg

Handheld Chlorine Dioxide analyzer CLO2-HNAG900

Handheld Chlorine Dioxide analyzer CLO2

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

(7).jpg

Handheld Formaldehyde gas detector CH2O-HNAG900

Handheld Formaldehyde gas detector CH2O

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: Formaldehyde (CH2O) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

1.jpg

Handheld nitrogen gas detector 0-100%vol-HNAG920

Handheld nitrogen gas detector 0-100%vol

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

微信图片_20251128190810_5177_3.jpg

Combustible Online Gas Detector LEL Alarm Monitor System-SK/MIC-600

Combustible Online Gas Detector LEL Alarm Monitor System

Detection gas:EX_Flammable-CH4 Range:0-100%LEL (3-100%LEL) / 0-5%VOL Detection Principle:Infrared Resolution:0.1%LEL_0.001%VOL Detection Accuracy:±2%F.S Model:SK/MIC-600

4 - 副本(1).jpg

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof-HNAG1000

Intrinsically Safe Carbon Monoxide Detector with Explosion Proof

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

5 - 副本(1).jpg

Fixed carbon monoxide detector RS485 4-20mA-HNAG1000

Fixed carbon monoxide detector RS485 4-20mA

Detection gas:CO,Carbon monoxide Range:0-1000ppm/0-5000ppm/custom Detection Principle:Electrochemistry Resolution:1ppm Detection Accuracy:±2%F.S Model:HNAG1000

3ADC7CFB70C07222EA7F04FE5D3CD26A.jpg

Portable Oxygen gas detector alarm 0-30%vol gas monitoring-HNAG920-O2

Portable Oxygen gas detector alarm 0-30%vol gas monitoring

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

2.jpg

industrial gas detector o2 pump suction Oxygen analyzer-HNAG920-O2

industrial gas detector o2 pump suction Oxygen analyzer

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Give us a free quote
Submit this form and our sales representative will contact you soon.
* Name
* Email
Phone
  • Angola+244
  • Afghanistan+93
  • Albania+355
  • Algeria+213
  • Andorra+376
  • Anguilla+1264
  • Antigua and Barbuda+1268
  • Argentina+54
  • Armenia+374
  • Ascension+247
  • Australia+61
  • Austria+43
  • Azerbaijan+994
  • Bahamas+1242
  • Bahrain+973
  • Bangladesh+880
  • Barbados+1246
  • Belarus+375
  • Belgium+32
  • Belize+501
  • Benin+229
  • Bermuda Is.+1441
  • Bolivia+591
  • Botswana+267
  • Brazil+55
  • Brunei+673
  • Bulgaria+359
  • Burkina+faso+226
  • Burma+95
  • Burundi+257
  • Cameroon+237
  • Canada+1
  • Cayman Is.+1345
  • Central African Republic+236
  • Chad+235
  • Chile+56
  • China+86
  • Colombia+57
  • Congo+242
  • Cook Is.+682
  • Costa Rica+506
  • Cuba+53
  • Cyprus+357
  • Czech Republic+420
  • Denmark+45
  • Djibouti+253
  • Dominica Rep.+1890
  • Ecuador+593
  • Egypt+20
  • EI Salvador+503
  • Estonia+372
  • Ethiopia+251
  • Fiji+679
  • Finland+358
  • France+33
  • French Guiana+594
  • Gabon+241
  • Gambia+220
  • Georgia+995
  • Germany+49
  • Ghana+233
  • Gibraltar+350
  • Greece+30
  • Grenada+1809
  • Guam+1671
  • Guatemala+502
  • Guinea+224
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hongkong+852
  • Hungary+36
  • Iceland+354
  • India+91
  • Indonesia+62
  • Iran+98
  • Iraq+964
  • Ireland+353
  • Israel+972
  • Italy+39
  • Ivory Coast+225
  • Jamaica+1876
  • Japan+81
  • Jordan+962
  • Kampuchea (Cambodia )+855
  • Kazakstan+327
  • Kenya+254
  • Korea+82
  • Kuwait+965
  • Kyrgyzstan+331
  • Laos+856
  • Latvia+371
  • Lebanon+961
  • Lesotho+266
  • Liberia+231
  • Libya+218
  • Liechtenstein+423
  • Lithuania+370
  • Luxembourg+352
  • Macao+853
  • Madagascar+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Mariana Is+1670
  • Martinique+596
  • Mauritius+230
  • Mexico+52
  • Moldova, Republic of+373
  • Monaco+377
  • Mongolia+976
  • Montserrat Is+1664
  • Morocco+212
  • Mozambique+258
  • Namibia+264
  • Nauru+674
  • Nepal+977
  • Netheriands Antilles+599
  • Netherlands+31
  • New Zealand+64
  • Nicaragua+505
  • Niger+227
  • Nigeria+234
  • North Korea+850
  • Norway+47
  • Oman+968
  • Pakistan+92
  • Panama+507
  • Papua New Cuinea+675
  • Paraguay+595
  • Peru+51
  • Philippines+63
  • Poland+48
  • French Polynesia+689
  • Portugal+351
  • Puerto Rico+1787
  • Qatar+974
  • Reunion+262
  • Romania+40
  • Russia+7
  • Saint Lueia+1758
  • Saint Vincent+1784
  • Samoa Eastern+684
  • Samoa Western+685
  • San Marino+378
  • Sao Tome and Principe+239
  • Saudi Arabia+966
  • Senegal+221
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Slovakia+421
  • Slovenia+386
  • Solomon Is+677
  • Somali+252
  • South Africa+27
  • Spain+34
  • Sri Lanka+94
  • St.Lucia+1758
  • St.Vincent+1784
  • Sudan+249
  • Suriname+597
  • Swaziland+268
  • Sweden+46
  • Switzerland+41
  • Syria+963
  • Taiwan+886
  • Tajikstan+992
  • Tanzania+255
  • Thailand+66
  • Togo+228
  • Tonga+676
  • Trinidad and Tobago+1809
  • Tunisia+216
  • Turkey+90
  • Turkmenistan+993
  • Uganda+256
  • Ukraine+380
  • United Arab Emirates+971
  • United Kiongdom+44
  • United States of America+1
  • Uruguay+598
  • Uzbekistan+233
  • Venezuela+58
  • Vietnam+84
  • Yemen+967
  • Yugoslavia+381
  • Zimbabwe+263
  • Zaire+243
  • Zambia+260
* Message