Model: SK/MIC-600-HCN

Measurement object: Hydrogen cyanide

Category: Products Fixed gas detector Stainless steel gas detector

Key words: Products

Model: SK/MIC-600-HCN

Measurement object: Hydrogen cyanide



Product Description

On-line hydrogen cyanide gas concentration detector product parameters

 

Output signal

① 4-20mA signal: standard 12-bit precision 4-20mA output chip, transmission distance 1Km

② RS485 signal: standard MODBUS RTU protocol, transmission distance 1Km

③ voltage signal: 0.4-2V,0-5V,0-10V output, optional (voltage output and current output two choose one)

④ Switching signal: standard 1 set of passive contact relay, capacity 220VAC3AV/24VDC3A

GPRS, 4G, WIFI, LORA, ZigBee and other wireless signals
Measuring gas hydrogen cyanide gas Detection principle Electrochemistry (other principles can be customized)
Range selection 0-100PPM (more range inquiry customer service) Resolution 0.1PPM
Sampling accuracy ±3%F.S Response time T90<10S
Working temperature -20~50 ℃ Working humidity 0-95%RH
Storage temperature -20~50 ℃ Preheating time 10S
Working current ≤50mA Working air pressure 86kpa-106kpa
Operating voltage DC5V±1%/DC24±1% Baud rate 9600
Installation method Wall-mounted installation Pipe installation Ceiling installation Bracket installation Warranty period 1 year
Exterior dimension 220*205*97(L*W*H)1.5Kg Service life 1-3 years
Protection level IP66 waterproof splash and short time rain Explosion-proof grade E x d I IC T 6
Receiving equipment User computer, control alarm, PLC, DCS, DDC, etc.
Alarm mode On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc.
Alarm Settings Standard configuration of two-level alarm, optional three-level alarm; alarm mode can be set: regular high and low alarm, interval control alarm
Connection cable

① Select three-core shielded cable for 4 ~ 20mA and four-core cable for RS485. When the distance exceeds 1000 m (with a detector), the single wire diameter shall be ≥ 1.5mm, and the shielding layer shall be connected to the ground.

② wireless transmission: can be built-in LORA, Zigbeg module, short-range wireless transmission; external GPRS/4G module, remote data transmission to the cloud platform, can be viewed on the computer side and mobile phone side of the history, not limited by distance (optional)

Optional accessories

Normal temperature and high humidity pretreatment system, high temperature and normal humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system, pressure reducing valve, flow meter, chloroform gas measurement, 24VDC or 220AC sampling pump (sampling distance is 10 meters), vacuum pump (sampling distance is more than 40 meters), 24V switching power supply, 220V to 24V power adapter.

Computer monitoring accessories: free upper computer software, USB to RS485 conversion cable, RS485 to network port converter if network transmission is required.

Mounting bracket

 

On-line hydrogen cyanide gas concentration detector product features

 

● Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static capabilities exceed national standards, and resist high-intensity pulse surge current impact. High reliability and stability.

● Standard bus RS485 and 4 ~ 20mA standard signals are output at the same time, one group of relay switch output, optional frequency output 200-1000Hz, 1~5V output, wireless transmission (10-50km or unlimited distance). It can be wired or wireless remote real-time monitoring, upload data to mobile phones or transmit to the Environmental Protection Bureau, other monitoring centers, monitoring equipment, and monitoring computers through local area networks and the Internet, and monitor the concentration of the site in real time through free upper computer software or gas alarm controllers.

● Compatible with all kinds of secondary table, data acquisition module, PLC, DCS system, can directly drive the solenoid valve, fan, alarm and other equipment, can also drive the intermediate relay to drive high-power equipment.

● Standard infrared remote control, can be achieved in dangerous situations without open cover operation.

● 2.5 inch HD color screen (TF) shows real-time concentration, temperature and humidity.

● Automatic zero tracking to prevent drift, temperature compensation, multi-level calibration, can also meet the national standard and local and provincial metrology bureau standards in various regions.

 

Application Scenarios


Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, pharmaceutical research, pharmaceutical production workshops, tobacco companies, environmental monitoring, school research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, Garbage treatment plant, tunnel construction, oil pipeline, gas filling station, underground gas pipeline maintenance, indoor air quality inspection, safety protection in hazardous places, aerospace, military equipment monitoring, etc.

 

 

 

On-line hydrogen cyanide gas concentration detector interface display introduction

 

The instrument has a total of 3 buttons, namely "add/cancel", "function/confirm", "move right/down" (hereinafter referred to as "add" ("cancel"), "function" ("confirm"), "move right" ("move left")). The three key positions are as follows. Press the "Function" button.

 

Internal diagram of online hydrogen cyanide gas concentration detector

 

On-line hydrogen cyanide gas concentration detector can be used stand-alone

or connectionManagement control machine with the use of wiring diagram

 

4-20mA Wiring Definition Chart RS485 Wiring Definition Chart

 

Installation position of online hydrogen cyanide gas concentration detector


According to the specific gravity and wind direction of the gas, the detector should be installed within one meter from the place where the gas may leak, so that the actual reaction speed of the detector is relatively fast. Otherwise, the concentration of hydrogen cyanide gas or toxic and harmful gas at the place where the detector is installed may not exceed the standard, while the local gas at the leak point has exceeded the standard, but the detector and the host cannot alarm.
 

The height of the detector should be more than 30cm from the ground to prevent water from splashing in. In general, the detection of harmful gases with a specific gravity less than that of the air, the probe should be installed above the house or equipment; the harmful gases with a specific gravity greater than that of the air, the probe should be installed close to the ground. The probe of the detector shall be installed downward. If it is installed outdoors, a rain shield shall be installed above the detector.

Note: The detection range of each probe in the open area is 60 square meters, and factors such as gas diffusion, wind direction, temperature, humidity and regional closure should also be considered. Protection measures such as dustproof, waterproof and high temperature protection should also be considered during installation.

 

Installation Method


Users can design their own fixed way. However, care should be taken to keep the sensor face of the probe perpendicular to the ground. After the probe is fixed, remove the screws on the upper cover of the shell, and insert the shielded (three-core 3 × 1.5mm) transmission cable through the wire passage. It is recommended to use shielded soft core (3 × 1.5mm) cable and connect the cable to the terminal position. After checking that the wiring is firm, fix the cable and the upper cover of the housing.

On-line hydrogen cyanide gas concentration detector product parameters

 

Output signal

① 4-20mA signal: standard 12-bit precision 4-20mA output chip, transmission distance 1Km

② RS485 signal: standard MODBUS RTU protocol, transmission distance 1Km

③ voltage signal: 0.4-2V,0-5V,0-10V output, optional (voltage output and current output two choose one)

④ Switching signal: standard 1 set of passive contact relay, capacity 220VAC3AV/24VDC3A

GPRS, 4G, WIFI, LORA, ZigBee and other wireless signals
Measuring gas hydrogen cyanide gas Detection principle Electrochemistry (other principles can be customized)
Range selection 0-100PPM (more range inquiry customer service) Resolution 0.1PPM
Sampling accuracy ±3%F.S Response time T90<10S
Working temperature -20~50 ℃ Working humidity 0-95%RH
Storage temperature -20~50 ℃ Preheating time 10S
Working current ≤50mA Working air pressure 86kpa-106kpa
Operating voltage DC5V±1%/DC24±1% Baud rate 9600
Installation method Wall-mounted installation Pipe installation Ceiling installation Bracket installation Warranty period 1 year
Exterior dimension 220*205*97(L*W*H)1.5Kg Service life 1-3 years
Protection level IP66 waterproof splash and short time rain Explosion-proof grade E x d I IC T 6
Receiving equipment User computer, control alarm, PLC, DCS, DDC, etc.
Alarm mode On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc.
Alarm Settings Standard configuration of two-level alarm, optional three-level alarm; alarm mode can be set: regular high and low alarm, interval control alarm
Connection cable

① Select three-core shielded cable for 4 ~ 20mA and four-core cable for RS485. When the distance exceeds 1000 m (with a detector), the single wire diameter shall be ≥ 1.5mm, and the shielding layer shall be connected to the ground.

② wireless transmission: can be built-in LORA, Zigbeg module, short-range wireless transmission; external GPRS/4G module, remote data transmission to the cloud platform, can be viewed on the computer side and mobile phone side of the history, not limited by distance (optional)

Optional accessories

Normal temperature and high humidity pretreatment system, high temperature and normal humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system, pressure reducing valve, flow meter, chloroform gas measurement, 24VDC or 220AC sampling pump (sampling distance is 10 meters), vacuum pump (sampling distance is more than 40 meters), 24V switching power supply, 220V to 24V power adapter.

Computer monitoring accessories: free upper computer software, USB to RS485 conversion cable, RS485 to network port converter if network transmission is required.

Mounting bracket

 

On-line hydrogen cyanide gas concentration detector product features

 

● Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static capabilities exceed national standards, and resist high-intensity pulse surge current impact. High reliability and stability.

● Standard bus RS485 and 4 ~ 20mA standard signals are output at the same time, one group of relay switch output, optional frequency output 200-1000Hz, 1~5V output, wireless transmission (10-50km or unlimited distance). It can be wired or wireless remote real-time monitoring, upload data to mobile phones or transmit to the Environmental Protection Bureau, other monitoring centers, monitoring equipment, and monitoring computers through local area networks and the Internet, and monitor the concentration of the site in real time through free upper computer software or gas alarm controllers.

● Compatible with all kinds of secondary table, data acquisition module, PLC, DCS system, can directly drive the solenoid valve, fan, alarm and other equipment, can also drive the intermediate relay to drive high-power equipment.

● Standard infrared remote control, can be achieved in dangerous situations without open cover operation.

● 2.5 inch HD color screen (TF) shows real-time concentration, temperature and humidity.

● Automatic zero tracking to prevent drift, temperature compensation, multi-level calibration, can also meet the national standard and local and provincial metrology bureau standards in various regions.

 

Application Scenarios


Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, pharmaceutical research, pharmaceutical production workshops, tobacco companies, environmental monitoring, school research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, Garbage treatment plant, tunnel construction, oil pipeline, gas filling station, underground gas pipeline maintenance, indoor air quality inspection, safety protection in hazardous places, aerospace, military equipment monitoring, etc.

 

 

 

On-line hydrogen cyanide gas concentration detector interface display introduction

 

The instrument has a total of 3 buttons, namely "add/cancel", "function/confirm", "move right/down" (hereinafter referred to as "add" ("cancel"), "function" ("confirm"), "move right" ("move left")). The three key positions are as follows. Press the "Function" button.

 

Internal diagram of online hydrogen cyanide gas concentration detector

 

On-line hydrogen cyanide gas concentration detector can be used stand-alone

or connectionManagement control machine with the use of wiring diagram

 

4-20mA Wiring Definition Chart RS485 Wiring Definition Chart

 

Installation position of online hydrogen cyanide gas concentration detector


According to the specific gravity and wind direction of the gas, the detector should be installed within one meter from the place where the gas may leak, so that the actual reaction speed of the detector is relatively fast. Otherwise, the concentration of hydrogen cyanide gas or toxic and harmful gas at the place where the detector is installed may not exceed the standard, while the local gas at the leak point has exceeded the standard, but the detector and the host cannot alarm.
 

The height of the detector should be more than 30cm from the ground to prevent water from splashing in. In general, the detection of harmful gases with a specific gravity less than that of the air, the probe should be installed above the house or equipment; the harmful gases with a specific gravity greater than that of the air, the probe should be installed close to the ground. The probe of the detector shall be installed downward. If it is installed outdoors, a rain shield shall be installed above the detector.

Note: The detection range of each probe in the open area is 60 square meters, and factors such as gas diffusion, wind direction, temperature, humidity and regional closure should also be considered. Protection measures such as dustproof, waterproof and high temperature protection should also be considered during installation.

 

Installation Method


Users can design their own fixed way. However, care should be taken to keep the sensor face of the probe perpendicular to the ground. After the probe is fixed, remove the screws on the upper cover of the shell, and insert the shielded (three-core 3 × 1.5mm) transmission cable through the wire passage. It is recommended to use shielded soft core (3 × 1.5mm) cable and connect the cable to the terminal position. After checking that the wiring is firm, fix the cable and the upper cover of the housing.

Product Recommendation
3df09478-abdc-41f9-81a9-d36134297dff.jpeg

On-line large dust concentration detection alarm TSP-

On-line large dust concentration detection alarm TSP

Category: Products On-line dust detector On-line dust concentration detector Key words:Products Model: SK/MIC-600-PM Measurement object: Dust/PM100/TSP

30b58148-24f6-444c-bfcb-b2b95b60323b.jpeg

On-line dust concentration detector alarm-

On-line dust concentration detector alarm

Category: On-line dust concentration detector On-line dust detector Key words: Products Model: SK/MIC-600-PM Measurement object: Dust/PM1.0/PM2.5/PM5/PM10

47629257-f1ea-4eec-bc53-de26a94fac2e.jpeg

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument-

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

75f6734e-0a0e-4bcb-a6c3-084bb3715f4f.jpeg

pump suction toxic gas online monitoring system H2S NH3 CO NO VOC gas detection alarm HCN CLO2 SIH4 CH3BR for industry-

pump suction toxic gas online monitoring system H2S NH3 CO NO VOC gas detection alarm HCN CLO2 SIH4 CH3BR for industry

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

4c874027-a1cb-4ae9-b15e-1b363a6218bf.jpeg

Pump-suction TVOC Combustible Gas Pretreatment Online Monitoring CH4 H2S Detection Alarm O2 Detector NOX SO2 Flue Gas-

Pump-suction TVOC Combustible Gas Pretreatment Online Monitoring CH4 H2S Detection Alarm O2 Detector NOX SO2 Flue Gas

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

14f07f91-d52d-4e87-9fe6-fe7ff2efda6c.jpeg

VOCS Pump Suction Combustible Gas Online Monitoring System Filtration Drainage flow rate control Output Signal: RS485/4-20mA-

VOCS Pump Suction Combustible Gas Online Monitoring System Filtration Drainage flow rate control Output Signal: RS485/4-20mA

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

4c874027-a1cb-4ae9-b15e-1b363a6218bf.jpeg

Pump Suction Toxic Gases Online Monitoring System H2S NH3 VOC Gas Detecting Alarm HCN CLO2 SIH4 CH3BR Exhaust Detector LEL PID-

Pump Suction Toxic Gases Online Monitoring System H2S NH3 VOC Gas Detecting Alarm HCN CLO2 SIH4 CH3BR Exhaust Detector LEL PID

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

7ee84ca6-9b56-4448-975d-2b7466b90170.jpeg

Industrial Fixed AsH3 Gas Detector Arsine analyzer Arsine concentration alarm PPM-

Industrial Fixed AsH3 Gas Detector Arsine analyzer Arsine concentration alarm PPM

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-AsH3 Measurement object: AsH3,Arsine

b0ee92ee-f70c-497a-8a0a-c51cb7fce5d6.jpeg

Online EX gas detector LEL monitors and LEL analyzers 0-100%LEL for the commercial and industrial sectors-

Online EX gas detector LEL monitors and LEL analyzers 0-100%LEL for the commercial and industrial sectors

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-O2 Measurement object: O2

7ee84ca6-9b56-4448-975d-2b7466b90170.jpeg

High precision Industrial Fixed Oxygen (O2) Gas Detector oxygen analyzer oxygen concentration alarm 0-30%VOL or 0-100%VOL-

High precision Industrial Fixed Oxygen (O2) Gas Detector oxygen analyzer oxygen concentration alarm 0-30%VOL or 0-100%VOL

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-O2 Measurement object: O2

7ee84ca6-9b56-4448-975d-2b7466b90170.jpeg

Online NH3 gas detector fixed Ammonia gas analyzer-

Online NH3 gas detector fixed Ammonia gas analyzer

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-NH3 Measurement object: NH3

a2d7ccec-bacb-4bd2-a854-9a722a7d8461.jpeg

Explosion-Proof CO Gas Analyzer Detector Alert Carbon Monoxide test Equipment Alarm for Underground Pipeline Sewage Well Cabin-

Explosion-Proof CO Gas Analyzer Detector Alert Carbon Monoxide test Equipment Alarm for Underground Pipeline Sewage Well Cabin

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600 Measurement object: CO

46ea6d27-bd54-41ee-8131-6f0665466726.jpeg

On-line portable h2s detector-

On-line portable h2s detector

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-AsH3 Measurement object: Hydrogen arsine

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

55b02247-8fa9-49a0-bb5b-dde66670baf7.jpeg

Portable single Gas detector LEL O2 CO H2S Detector CH4 VOC Analyzer for Petrochemical industry Coal mines and underground operations-

Portable single Gas detector LEL O2 CO H2S Detector CH4 VOC Analyzer for Petrochemical industry Coal mines and underground operations

Category: Portable gas detector Portable gas detector Key words: Portable gas detector Model: SK/MIC-800 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/...

07142cce-53fd-4615-a916-b3da780ca451.jpeg

High Accuracy Pump Suction Portable Hydrogen Sulfide Gas Detector Handheld H2S Concentration Analyzer for Biogas-

High Accuracy Pump Suction Portable Hydrogen Sulfide Gas Detector Handheld H2S Concentration Analyzer for Biogas

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920-H2S Measurement object: H2S,Hydrogen Sulfide

fc569fa9-df9f-4196-835e-0e98e0b2791a.jpeg

Portable Combustible Gas Detector CH4 Gas Analyzer EX Gas Analyzer Liquefied Petroleum Gas Detector LPG for Industry 0-100%LEL-

Portable Combustible Gas Detector CH4 Gas Analyzer EX Gas Analyzer Liquefied Petroleum Gas Detector LPG for Industry 0-100%LEL

Category: Products Portable gas detector Portable gas detector Key words: Products Model: SK/MIC-800-NH3 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/...

48485f70-7924-4192-af8c-6a8bc7038bd6.jpeg

Handheld Ethyl chloroformate gas detector C3H5O2Cl gas concentrartion detection C3H5O2Cl PID sensor PPM-

Handheld Ethyl chloroformate gas detector C3H5O2Cl gas concentrartion detection C3H5O2Cl PID sensor PPM

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920-C3H5O2C Measurement object: C3H5O2C,Ethyl chloroformate

f2a550a9-eeaf-420a-8e13-02cf01e80ae8.jpeg

Portable Methanol gas Detector high precision detection Methanol CH4O gas alarm PID sensor-

Portable Methanol gas Detector high precision detection Methanol CH4O gas alarm PID sensor

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920-CH4O Measurement object: CH4O,Methanol

30b58148-24f6-444c-bfcb-b2b95b60323b.jpeg

Dust Concentration Detector PM2.5/PM10 Analyzer TSP Alarm Workshop Electrostatic Charge Detection Equipment Testing Equipment-

Dust Concentration Detector PM2.5/PM10 Analyzer TSP Alarm Workshop Electrostatic Charge Detection Equipment Testing Equipment

Category: Products On-line dust detector On-line dust concentration detector Key words: Products Model: SK/MIC-600-PM Measurement object: PM,0-1000,10000ug/m3

3df09478-abdc-41f9-81a9-d36134297dff.jpeg

On-line large dust concentration detection alarm TSP-

On-line large dust concentration detection alarm TSP

Category: Products On-line dust detector On-line dust concentration detector Key words:Products Model: SK/MIC-600-PM Measurement object: Dust/PM100/TSP

30b58148-24f6-444c-bfcb-b2b95b60323b.jpeg

On-line dust concentration detector alarm-

On-line dust concentration detector alarm

Category: On-line dust concentration detector On-line dust detector Key words: Products Model: SK/MIC-600-PM Measurement object: Dust/PM1.0/PM2.5/PM5/PM10

47629257-f1ea-4eec-bc53-de26a94fac2e.jpeg

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument-

Multi-gas Integrated Pretreatment Online Monitoring System Toxic Gas Analyzer RTO Leak-proof Detection Alarm Instrument

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

75f6734e-0a0e-4bcb-a6c3-084bb3715f4f.jpeg

pump suction toxic gas online monitoring system H2S NH3 CO NO VOC gas detection alarm HCN CLO2 SIH4 CH3BR for industry-

pump suction toxic gas online monitoring system H2S NH3 CO NO VOC gas detection alarm HCN CLO2 SIH4 CH3BR for industry

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

4c874027-a1cb-4ae9-b15e-1b363a6218bf.jpeg

Pump-suction TVOC Combustible Gas Pretreatment Online Monitoring CH4 H2S Detection Alarm O2 Detector NOX SO2 Flue Gas-

Pump-suction TVOC Combustible Gas Pretreatment Online Monitoring CH4 H2S Detection Alarm O2 Detector NOX SO2 Flue Gas

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

14f07f91-d52d-4e87-9fe6-fe7ff2efda6c.jpeg

VOCS Pump Suction Combustible Gas Online Monitoring System Filtration Drainage flow rate control Output Signal: RS485/4-20mA-

VOCS Pump Suction Combustible Gas Online Monitoring System Filtration Drainage flow rate control Output Signal: RS485/4-20mA

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

4c874027-a1cb-4ae9-b15e-1b363a6218bf.jpeg

Pump Suction Toxic Gases Online Monitoring System H2S NH3 VOC Gas Detecting Alarm HCN CLO2 SIH4 CH3BR Exhaust Detector LEL PID-

Pump Suction Toxic Gases Online Monitoring System H2S NH3 VOC Gas Detecting Alarm HCN CLO2 SIH4 CH3BR Exhaust Detector LEL PID

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

7ee84ca6-9b56-4448-975d-2b7466b90170.jpeg

Industrial Fixed AsH3 Gas Detector Arsine analyzer Arsine concentration alarm PPM-

Industrial Fixed AsH3 Gas Detector Arsine analyzer Arsine concentration alarm PPM

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-AsH3 Measurement object: AsH3,Arsine

b0ee92ee-f70c-497a-8a0a-c51cb7fce5d6.jpeg

Online EX gas detector LEL monitors and LEL analyzers 0-100%LEL for the commercial and industrial sectors-

Online EX gas detector LEL monitors and LEL analyzers 0-100%LEL for the commercial and industrial sectors

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-O2 Measurement object: O2

7ee84ca6-9b56-4448-975d-2b7466b90170.jpeg

High precision Industrial Fixed Oxygen (O2) Gas Detector oxygen analyzer oxygen concentration alarm 0-30%VOL or 0-100%VOL-

High precision Industrial Fixed Oxygen (O2) Gas Detector oxygen analyzer oxygen concentration alarm 0-30%VOL or 0-100%VOL

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-O2 Measurement object: O2

7ee84ca6-9b56-4448-975d-2b7466b90170.jpeg

Online NH3 gas detector fixed Ammonia gas analyzer-

Online NH3 gas detector fixed Ammonia gas analyzer

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-NH3 Measurement object: NH3

a2d7ccec-bacb-4bd2-a854-9a722a7d8461.jpeg

Explosion-Proof CO Gas Analyzer Detector Alert Carbon Monoxide test Equipment Alarm for Underground Pipeline Sewage Well Cabin-

Explosion-Proof CO Gas Analyzer Detector Alert Carbon Monoxide test Equipment Alarm for Underground Pipeline Sewage Well Cabin

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600 Measurement object: CO

46ea6d27-bd54-41ee-8131-6f0665466726.jpeg

On-line portable h2s detector-

On-line portable h2s detector

Category: Products Fixed gas detector Fixed gas detector Key words: Products Model: SK/MIC-600-AsH3 Measurement object: Hydrogen arsine

3cba4c9a-c6c2-4f1b-a9c6-150d4823fcc2.jpeg

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin-

Trending pump suction diffusion portable combustible gas detector co co2 no no2 toxic gas detector Wireless transmission for Underground pipeline Sewage well Cabin

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Give us a free quote
Submit this form and our sales representative will contact you soon.
* Name
* Email
Phone
  • Angola+244
  • Afghanistan+93
  • Albania+355
  • Algeria+213
  • Andorra+376
  • Anguilla+1264
  • Antigua and Barbuda+1268
  • Argentina+54
  • Armenia+374
  • Ascension+247
  • Australia+61
  • Austria+43
  • Azerbaijan+994
  • Bahamas+1242
  • Bahrain+973
  • Bangladesh+880
  • Barbados+1246
  • Belarus+375
  • Belgium+32
  • Belize+501
  • Benin+229
  • Bermuda Is.+1441
  • Bolivia+591
  • Botswana+267
  • Brazil+55
  • Brunei+673
  • Bulgaria+359
  • Burkina+faso+226
  • Burma+95
  • Burundi+257
  • Cameroon+237
  • Canada+1
  • Cayman Is.+1345
  • Central African Republic+236
  • Chad+235
  • Chile+56
  • China+86
  • Colombia+57
  • Congo+242
  • Cook Is.+682
  • Costa Rica+506
  • Cuba+53
  • Cyprus+357
  • Czech Republic+420
  • Denmark+45
  • Djibouti+253
  • Dominica Rep.+1890
  • Ecuador+593
  • Egypt+20
  • EI Salvador+503
  • Estonia+372
  • Ethiopia+251
  • Fiji+679
  • Finland+358
  • France+33
  • French Guiana+594
  • Gabon+241
  • Gambia+220
  • Georgia+995
  • Germany+49
  • Ghana+233
  • Gibraltar+350
  • Greece+30
  • Grenada+1809
  • Guam+1671
  • Guatemala+502
  • Guinea+224
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hongkong+852
  • Hungary+36
  • Iceland+354
  • India+91
  • Indonesia+62
  • Iran+98
  • Iraq+964
  • Ireland+353
  • Israel+972
  • Italy+39
  • Ivory Coast+225
  • Jamaica+1876
  • Japan+81
  • Jordan+962
  • Kampuchea (Cambodia )+855
  • Kazakstan+327
  • Kenya+254
  • Korea+82
  • Kuwait+965
  • Kyrgyzstan+331
  • Laos+856
  • Latvia+371
  • Lebanon+961
  • Lesotho+266
  • Liberia+231
  • Libya+218
  • Liechtenstein+423
  • Lithuania+370
  • Luxembourg+352
  • Macao+853
  • Madagascar+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Mariana Is+1670
  • Martinique+596
  • Mauritius+230
  • Mexico+52
  • Moldova, Republic of+373
  • Monaco+377
  • Mongolia+976
  • Montserrat Is+1664
  • Morocco+212
  • Mozambique+258
  • Namibia+264
  • Nauru+674
  • Nepal+977
  • Netheriands Antilles+599
  • Netherlands+31
  • New Zealand+64
  • Nicaragua+505
  • Niger+227
  • Nigeria+234
  • North Korea+850
  • Norway+47
  • Oman+968
  • Pakistan+92
  • Panama+507
  • Papua New Cuinea+675
  • Paraguay+595
  • Peru+51
  • Philippines+63
  • Poland+48
  • French Polynesia+689
  • Portugal+351
  • Puerto Rico+1787
  • Qatar+974
  • Reunion+262
  • Romania+40
  • Russia+7
  • Saint Lueia+1758
  • Saint Vincent+1784
  • Samoa Eastern+684
  • Samoa Western+685
  • San Marino+378
  • Sao Tome and Principe+239
  • Saudi Arabia+966
  • Senegal+221
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Slovakia+421
  • Slovenia+386
  • Solomon Is+677
  • Somali+252
  • South Africa+27
  • Spain+34
  • Sri Lanka+94
  • St.Lucia+1758
  • St.Vincent+1784
  • Sudan+249
  • Suriname+597
  • Swaziland+268
  • Sweden+46
  • Switzerland+41
  • Syria+963
  • Taiwan+886
  • Tajikstan+992
  • Tanzania+255
  • Thailand+66
  • Togo+228
  • Tonga+676
  • Trinidad and Tobago+1809
  • Tunisia+216
  • Turkey+90
  • Turkmenistan+993
  • Uganda+256
  • Ukraine+380
  • United Arab Emirates+971
  • United Kiongdom+44
  • United States of America+1
  • Uruguay+598
  • Uzbekistan+233
  • Venezuela+58
  • Vietnam+84
  • Yemen+967
  • Yugoslavia+381
  • Zimbabwe+263
  • Zaire+243
  • Zambia+260
* Message