Detection gas:H2S
Range:0-100ppm
Detection Principle:Electrochemistry
Resolution:0.1ppm
Detection Accuracy:±2%F.S
Model:HNAG1000-H2S
Detection gas:H2S
Range:0-100ppm
Detection Principle:Electrochemistry
Resolution:0.1ppm
Detection Accuracy:±2%F.S
Model:HNAG1000-H2S
●Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static capabilities exceed national standards, and can withstand high-intensity pulse surge current impacts. High reliability and stability.
●Standard bus RS485 and 4~20mA standard signals are output simultaneously, 1 set of relay switching output, optional frequency output 200-1000Hz, 1~5V output, wireless transmission (10-50 kilometers or unlimited distance). It can be wired or wireless remote real-time monitoring, and the data can be uploaded to a mobile phone or transmitted to the Environmental Protection Bureau, other monitoring centers, monitoring equipment, and monitoring computers through LAN or the Internet, and the on-site concentration can be monitored in real time through free host computer software or gas alarm controllers.
●It is compatible with various secondary meters, data acquisition modules, PLC, and DCS systems. It can directly drive solenoid valves, fans, alarms and other equipment, and can also drive high-power equipment by driving intermediate relays.
●The standard infrared remote control enables operation without opening the cover in dangerous situations.
●2.5-inch high-definition color screen (TF) displays real-time concentration, temperature, humidity.
●Automatically tracks zero point to prevent drift, temperature compensation, multi-level calibration, and can comply with national standards and local and provincial metrology bureau standards in various regions.
![]() |
![]() |
![]() |
![]() |
Hydrogen Sulfide (H2S) Detection – Essential for Industrial Safety
H2S is a deadly gas commonly found in oil refineries, wastewater plants, and confined spaces. Reliable hydrogen sulfide gas detectors and hydrogen sulfide monitors are critical to protect workers from exposure, with real-time alerts and precision sensors to prevent accidents.
Q: What Types of H2S Gas Detectors Are Best for Industrial Use?
A: Choosing the right H2S detector depends on your industry’s risks. Here are the top types used in high-risk environments:
1. Fixed H2S Gas Detectors (Continuous Monitoring)
Best for: Oil & gas facilities, chemical plants, and sewage treatment plants where leaks are a constant threat.
Key Features:
24/7 monitoring with alarm integration into control rooms.
Rugged design for harsh environments (corrosion-resistant for offshore rigs).
Complies with OSHA and NIOSH safety standards .
2. Portable H2S Monitors (Personal Safety)
Best for: Maintenance crews, first responders, and workers entering confined spaces (e.g., tanks, pipelines).
Key Features:
Clip-on design with vibrating, visual, and loud (95dB) alarms.
Long battery life (18+ hours) for shift-long protection.
Data logging to track exposure levels for compliance reports .
3. Explosion-Proof H2S Detectors (Hazardous Areas)
Best for: Refineries, mining, and biogas plants where flammable gases coexist with H2S.
Key Features:
ATEX/IECEx certification for Zone 0/1 explosive atmospheres.
Stainless steel housing to resist chemical corrosion.
4. Wireless H2S Monitoring Systems (Smart Safety)
Emerging Trend: IoT-enabled detectors transmit real-time data to cloud dashboards, allowing remote monitoring across multiple sites—ideal for large facilities like petrochemical complexes .
Critical Factors When Selecting an H2S Detector
Accuracy: Look for ≤1 ppm detection levels (H2S is lethal at 100 ppm).
Industry-Specific Needs: Offshore rigs require waterproof models, while pulp/paper mills need filters against false alarms from other gases.
●Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static capabilities exceed national standards, and can withstand high-intensity pulse surge current impacts. High reliability and stability.
●Standard bus RS485 and 4~20mA standard signals are output simultaneously, 1 set of relay switching output, optional frequency output 200-1000Hz, 1~5V output, wireless transmission (10-50 kilometers or unlimited distance). It can be wired or wireless remote real-time monitoring, and the data can be uploaded to a mobile phone or transmitted to the Environmental Protection Bureau, other monitoring centers, monitoring equipment, and monitoring computers through LAN or the Internet, and the on-site concentration can be monitored in real time through free host computer software or gas alarm controllers.
●It is compatible with various secondary meters, data acquisition modules, PLC, and DCS systems. It can directly drive solenoid valves, fans, alarms and other equipment, and can also drive high-power equipment by driving intermediate relays.
●The standard infrared remote control enables operation without opening the cover in dangerous situations.
●2.5-inch high-definition color screen (TF) displays real-time concentration, temperature, humidity.
●Automatically tracks zero point to prevent drift, temperature compensation, multi-level calibration, and can comply with national standards and local and provincial metrology bureau standards in various regions.




Hydrogen Sulfide (H2S) Detection – Essential for Industrial Safety
H2S is a deadly gas commonly found in oil refineries, wastewater plants, and confined spaces. Reliable hydrogen sulfide gas detectors and hydrogen sulfide monitors are critical to protect workers from exposure, with real-time alerts and precision sensors to prevent accidents.
Q: What Types of H2S Gas Detectors Are Best for Industrial Use?
A: Choosing the right H2S detector depends on your industry’s risks. Here are the top types used in high-risk environments:
1. Fixed H2S Gas Detectors (Continuous Monitoring)
Best for: Oil & gas facilities, chemical plants, and sewage treatment plants where leaks are a constant threat.
Key Features:
24/7 monitoring with alarm integration into control rooms.
Rugged design for harsh environments (corrosion-resistant for offshore rigs).
Complies with OSHA and NIOSH safety standards .
2. Portable H2S Monitors (Personal Safety)
Best for: Maintenance crews, first responders, and workers entering confined spaces (e.g., tanks, pipelines).
Key Features:
Clip-on design with vibrating, visual, and loud (95dB) alarms.
Long battery life (18+ hours) for shift-long protection.
Data logging to track exposure levels for compliance reports .
3. Explosion-Proof H2S Detectors (Hazardous Areas)
Best for: Refineries, mining, and biogas plants where flammable gases coexist with H2S.
Key Features:
ATEX/IECEx certification for Zone 0/1 explosive atmospheres.
Stainless steel housing to resist chemical corrosion.
4. Wireless H2S Monitoring Systems (Smart Safety)
Emerging Trend: IoT-enabled detectors transmit real-time data to cloud dashboards, allowing remote monitoring across multiple sites—ideal for large facilities like petrochemical complexes .
Critical Factors When Selecting an H2S Detector
Accuracy: Look for ≤1 ppm detection levels (H2S is lethal at 100 ppm).
Industry-Specific Needs: Offshore rigs require waterproof models, while pulp/paper mills need filters against false alarms from other gases.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Discover the Combustible Online Gas Detector LEL Alarm Monitor System. This advanced system is designed for real - time detection of combustible gases. It offers high - precision monitoring, rapid alarm response to ensure safety in environments with potential gas hazards. Ideal for industrial settings, it helps prevent gas - related accidents and provides reliable data for better management.

Discover our Intrinsically Safe Carbon Monoxide Detector with Explosion Proof. Ideal for hazardous environments, it offers reliable CO detection. Built - in safety features prevent explosions, ensuring maximum protection. High - quality sensors provide accurate readings. Suitable for industrial sites, mines, and more. Keep your workplace safe with this top - notch detector.

Explore our fixed carbon monoxide detector with RS485 and 4 - 20mA interfaces. Ideal for continuous CO monitoring in industrial and commercial settings. It offers high - precision detection, reliable performance, and seamless integration with existing systems. Ensure safety and compliance with this advanced detector.

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Thermal conductivity Gas: helium (He) Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Explore our fixed hydrogen chloride detector (HCl). It offers reliable and accurate detection of hydrogen chloride gas. With advanced technology, it can quickly sense HCl in various environments, ensuring safety. Ideal for industrial settings, chemical plants, and places where HCl gas may be present. Our detector is easy to install and operate, providing continuous monitoring and timely alerts. Protect your workplace and personnel from HCl hazards with our high - quality fixed detector.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Hydrogen Fluoride (HF) Range: 0-10ppm,0-50ppm,0-100ppm Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethanol(C2H6O) Range: 0-10ppm,0-50ppm,0-100ppm,Custom Resolution: 0.01ppm,0.1ppm,1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Electrochemistry Gas: Ethylene (C2H4) Range: 0-10ppm,0-50ppm,0-100ppm,0-200ppm. Resolution: 0.01ppm,0.1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Acetylene (C2H2). Range: 0-100%LEL Resolution: 0.1LEL. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle: PID Gas: Methyl Bromide (CH3Br). Range: 0 to 50/100/200/500/1000/2000/3000ppm Resolution: 0.01ppm;0.1ppm;1ppm. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction and Diffusion Detection Principle:Electrochemistry Gas: ozone (O3) Range: 0-50PPM,0-100PPM. Resolution: 0.01PPM,0.1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction and Diffusion Detection Principle: Infrared NDIR Gas: Sulfur hexafluoride (SF6). Range: 0-1000ppm,0-3000PPM,0-5000PPM. Resolution: 1PPM. Accuracy: ≤±2% F.S.

Model: HNAG900 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: Chlorine Dioxide/CLO2 Range: 0-10ppm;0-1ppm. Resolution: 0.01PPM. Accuracy: ≤±2% F.S.

Model: HNAG920 Sampling Method: Pumping Suction Detection Principle: Electrochemistry Gas: N2 Range: 0-100%vol Resolution: 1%vol. Accuracy: ≤±2% F.S.

Category: Products Portable gas detector Portable gas detector Key words: Products Model: HNAG920 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/CH3BR/SO2F2/F2/HF/C2H2/CS2/SF6/C2H...

Discover the Combustible Online Gas Detector LEL Alarm Monitor System. This advanced system is designed for real - time detection of combustible gases. It offers high - precision monitoring, rapid alarm response to ensure safety in environments with potential gas hazards. Ideal for industrial settings, it helps prevent gas - related accidents and provides reliable data for better management.

Discover our Intrinsically Safe Carbon Monoxide Detector with Explosion Proof. Ideal for hazardous environments, it offers reliable CO detection. Built - in safety features prevent explosions, ensuring maximum protection. High - quality sensors provide accurate readings. Suitable for industrial sites, mines, and more. Keep your workplace safe with this top - notch detector.

Explore our fixed carbon monoxide detector with RS485 and 4 - 20mA interfaces. Ideal for continuous CO monitoring in industrial and commercial settings. It offers high - precision detection, reliable performance, and seamless integration with existing systems. Ensure safety and compliance with this advanced detector.

Detection gas:O2/Oxygen Range:0-30%VOL (0-25%VOL) / 0-100%VOL Detection Principle:Electrochemistry Resolution:0.1%VOL/0.01%VOL Detection Accuracy:±2%F.S Model:HNAG920